Your browser doesn't support javascript.
loading
Simultaneous determination of cis-permethrin and trans-permethrin in rat plasma and brain tissue using gas chromatography-negative chemical ionization mass spectrometry.
Hooshfar, Shirin; Gullick, Darren R; Linzey, Michael R; Mortuza, Tanzir; Abdel Rahman, Mona Hamdy; Rogers, Clinton A; Bruckner, James V; White, Catherine A; Bartlett, Michael G.
Afiliação
  • Hooshfar S; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • Gullick DR; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • Linzey MR; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • Mortuza T; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • Abdel Rahman MH; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • Rogers CA; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • Bruckner JV; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • White CA; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States.
  • Bartlett MG; Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, United States. Electronic address: mgbart@uga.edu.
Article em En | MEDLINE | ID: mdl-28651172
ABSTRACT
A sensitive method for the simultaneous determination of cis-permethrin (cis-PERM) and trans-permethrin (trans-PERM) in small volumes (100µL) of rat plasma and brain homogenate was developed, using a liquid-liquid extraction for sample preparation and gas chromatography-negative chemical ionization mass spectrometry (GCNCI-MS) for detection. Quantitation of trace levels of the insecticide in small volumes of biological samples is essential to support toxicokinetic studies in small animals. There are currently no validated methods in the literature for determining cis-PERM and trans- PERM in volumes as low as 100µL of rat plasma or brain homogenate. The method provided a linear range of 0.2-150.0ng/mL for analytes in both matrices. The intra- and inter-batch precision (as% relative standard deviation, RSD) and accuracy (as relative error, RE) of the method were better than 20% at the limit of quantitation and better than 15% across the remaining linear range. The validated method was applied in a toxicokinetic study in adult rats with oral dosing of 10mg/kg (cis-PERM) and 100mg/kg (trans-PERM) in corn oil. cis-PERM and trans- PERM were monitored in rat plasma and brain tissue samples for 6h following dosing, and both analytes were detected in all plasma and brain samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Química Encefálica / Permetrina / Cromatografia Gasosa-Espectrometria de Massas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Química Encefálica / Permetrina / Cromatografia Gasosa-Espectrometria de Massas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article