Your browser doesn't support javascript.
loading
123I-Meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients showing scans without evidence of dopaminergic deficits (SWEDDs).
Yoshii, Fumihito; Moriya, Yusuke; Ohnuki, Tomohide; Ryo, Masafuchi; Takahashi, Wakoh; Kohara, Saori; Hashimoto, Jun.
Afiliação
  • Yoshii F; Department of Neurology, Saiseikai Hiratsuka Hospital, 37-1 Tateno-cho, Hiratsuka, 254-0046, Japan; Department of Neurology, Tokai University Oiso Hospital, 21-1 Gakkyou, Oiso, Naka-gun, 259-0198, Japan. Electronic address: yoshii@is.icc.u-tokai.ac.jp.
  • Moriya Y; Department of Neurology, Tokai University Oiso Hospital, 21-1 Gakkyou, Oiso, Naka-gun, 259-0198, Japan.
  • Ohnuki T; Department of Neurology, Tokai University Oiso Hospital, 21-1 Gakkyou, Oiso, Naka-gun, 259-0198, Japan.
  • Ryo M; Department of Neurology, Tokai University Oiso Hospital, 21-1 Gakkyou, Oiso, Naka-gun, 259-0198, Japan.
  • Takahashi W; Department of Neurology, Tokai University Oiso Hospital, 21-1 Gakkyou, Oiso, Naka-gun, 259-0198, Japan.
  • Kohara S; Department of Clinical Technology, Tokai University Hospital, 143 Simokasuya, Isehara, 259-1193, Japan.
  • Hashimoto J; Department of Radiology, Tokai University School of Medicine, 143 Simokasuya, Isehara, 259-1193, Japan.
Clin Neurol Neurosurg ; 160: 73-77, 2017 Sep.
Article em En | MEDLINE | ID: mdl-28689103
ABSTRACT

OBJECTIVE:

Scans without evidence of dopaminergic deficits (SWEDDs) in dopamine transporter single-photon emission computed tomography (DAT-SPECT) are found in 3.6-19.6% of patients with clinically suspected Parkinson's disease (PD). We investigated whether combined use of 123I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy would be helpful to differentiate PD among SWEDDs patients. PATIENTS AND

METHODS:

145 patients with clinically suspected PD underwent both DAT-SPECT and MIBG myocardial scintigraphy. Striatal binding ratio (SBR) of DAT-SPECT and heart-to-mediastinal (H/M) ratio and washout rate (WR) of MIBG myocardial scintigraphy were calculated.

RESULTS:

Among 18 SWEDDs patients (12.4%), 11 were finally diagnosed with PD based on follow-up for at least two years after the DAT-SPECT and MIGB myocardial scintigraphy scans. Among the latter group, 8 patients showed an H/M ratio of less than 2.2, and 9 showed WR above 30%.

CONCLUSION:

Our results indicate that the combination of low H/M ratio and high WR of MIBG myocardial scintigraphy of SWEDDs patients may be helpful for detection of PD patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Tropanos / Tomografia Computadorizada de Emissão de Fóton Único / Compostos Radiofarmacêuticos / 3-Iodobenzilguanidina / Imagem de Perfusão do Miocárdio Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Tropanos / Tomografia Computadorizada de Emissão de Fóton Único / Compostos Radiofarmacêuticos / 3-Iodobenzilguanidina / Imagem de Perfusão do Miocárdio Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article