Your browser doesn't support javascript.
loading
Pseudoexfoliation signs in the anterior segment assessed by optical coherence tomography and Scheimpflug device. / Evaluación de los signos de la pseudoexfoliación en el segmento anterior mediante tomografía de coherencia óptica y cámara de Scheimpflug.
Fernández-Vigo, J I; de-Pablo Gómez de Liaño, L; Sánchez-Guillen, I; Macarro-Merino, A; Fernández-Vigo, C; García-Feijóo, J; Fernández-Vigo, J A.
Afiliação
  • Fernández-Vigo JI; Departamento de Oftalmología, Hospital Universitario Clínico San Carlos, Instituto de Investigación Sanitaria San Carlos (IdISSC), Madrid, España; Centro Internacional de Oftalmología Avanzada, Madrid, España. Electronic address: jfvigo@hotmail.com.
  • de-Pablo Gómez de Liaño L; Centro Internacional de Oftalmología Avanzada, Madrid, España; Departamento de Oftalmología, Hospital Universitario 12 de Octubre, Madrid, España.
  • Sánchez-Guillen I; Centro Internacional de Oftalmología Avanzada, Madrid, España.
  • Macarro-Merino A; Centro Internacional de Oftalmología Avanzada, Madrid, España.
  • Fernández-Vigo C; Centro Internacional de Oftalmología Avanzada, Madrid, España.
  • García-Feijóo J; Departamento de Oftalmología, Hospital Universitario Clínico San Carlos, Instituto de Investigación Sanitaria San Carlos (IdISSC), Madrid, España.
  • Fernández-Vigo JA; Centro Internacional de Oftalmología Avanzada, Madrid, España; Departamento de Oftalmología, Universidad de Extremadura , Badajoz, España.
Arch Soc Esp Oftalmol (Engl Ed) ; 93(2): 53-59, 2018 Feb.
Article em En, Es | MEDLINE | ID: mdl-28743412
ABSTRACT

OBJECTIVE:

To evaluate different anterior segment parameters in eyes with pseudoexfoliation (PSX), fellow eyes, and controls using optical coherence tomography and a Scheimpflug imaging system.

METHODS:

Three groups were studied 44 eyes of 44 patients with PSX, 30 clinically unaffected fellow eyes, and 148 eyes of 148 healthy controls. The anterior chamber depth and volume, corneal volume and thickness, pupil diameter and corneal densitometry were measured using a Scheimpflug imaging system (Pentacam, Oculus Inc.; Wetzlar, Germany). The angle width, the length and area of the trabecular meshwork, and the iris thickness were measured using an optical coherence tomography RTVue 100 device (Optovue, Fremont, CA, USA). The presence of PSX deposits was also assessed by OCT.

RESULTS:

There were no differences in the anterior chamber volume or depth in the corneal volume or central thickness (P≥.228). The corneal densitometry was similar between PSX and fellow eyes; however it was greater than in the control group (P<.001). As regards the parameters measured by OCT, there were no differences in the angle width or in the trabecular meshwork size between the 3 groups; however, the iris was thinner in controls (P=.005). In all patients the PSX deposits were correctly visualised by OCT after the identification by biomicroscopy.

CONCLUSIONS:

There were no differences in the anterior segment biometric measurements between patients with PSX and controls, although the corneal densitometry and iris thickness were greater in the PSX and fellow eyes groups.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Síndrome de Exfoliação / Tomografia de Coerência Óptica / Segmento Anterior do Olho Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En / Es Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Síndrome de Exfoliação / Tomografia de Coerência Óptica / Segmento Anterior do Olho Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En / Es Ano de publicação: 2018 Tipo de documento: Article