Your browser doesn't support javascript.
loading
Long-term complications, reoperations and survival following cardioverter-defibrillator implant.
Hawkins, Nathaniel Mark; Grubisic, Maja; Andrade, Jason G; Huang, Flora; Ding, Lillian; Gao, Min; Bashir, Jamil.
Afiliação
  • Hawkins NM; Division of Cardiology, University of British Columbia, Vancouver, Canada.
  • Grubisic M; BC Centre for Improved Cardiovascular Health, Vancouver, Canada.
  • Andrade JG; Division of Cardiology, University of British Columbia, Vancouver, Canada.
  • Huang F; University of British Columbia, Vancouver, Canada.
  • Ding L; Cardiac Services of British Columbia, Vancouver, Canada.
  • Gao M; BC Centre for Improved Cardiovascular Health, Vancouver, Canada.
  • Bashir J; Division of Cardiovascular Surgery, University of British Columbia, Vancouver, Canada.
Heart ; 104(3): 237-243, 2018 02.
Article em En | MEDLINE | ID: mdl-28747313
OBJECTIVE: Implantable cardioverter-defibrillators (ICDs) reduce risk of death in select populations, but are also associated with harms. We aimed to characterise long-term complications and reoperation rate. METHODS: We assessed the rate, cumulative incidence and predictors of long-term reoperation and survival using a prospective, multicentre registry serving British Columbia in Canada, a universal single payer healthcare system with 4.5 million residents. 3410 patients (mean 63.3 years, 81.7% male) with new primary (n=1854) or secondary prevention (n=1556) ICD implant from 2003 to 2012 were followed for a median of 34 months (single chamber n=1069, dual chamber n=1905, biventricular n=436). Independent predictors of adverse outcomes were defined using Cox regression models. RESULTS: The overall reoperation rate was 12.0% per patient-year, and less for single vs dual vs biventricular ICDs (9.1% vs 12.5% vs 17.8% per patient-year, respectively). The Kaplan-Meier complication estimates (excluding generator end of life) at 1, 3 and 5 years were respectively: single chamber 10.2%, 16.2% and 21.6%; dual 11.7%, 19.1% and 27.4% and biventricular 15.9%, 22.2% and 24.7%. Cardiac resynchronisation therapy had the highest rate of early lead complications, but lower long-term need for upgrade. Device complexity, age and atrial fibrillation were key determinants of complications. Overall mortality at 1, 3 and 5 years was 5.4%, 17.4% and 32.7%, respectively. In younger patients, observed 5-year survival approached the expected survival in the general population (relative survival ratio=0.96 (0.90-0.98)). With increasing age, observed survival steadily declined relative to expected. CONCLUSIONS: In a prospective registry capturing all procedures, complication and reoperation rates following de novo ICD implantation were high. Shared decision making must carefully consider these factors.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Desfibriladores Implantáveis Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Desfibriladores Implantáveis Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2018 Tipo de documento: Article