Your browser doesn't support javascript.
loading
Prediction of haematocrit in dried blood spots from the measurement of haemoglobin using commercially available sodium lauryl sulphate.
Richardson, G; Marshall, D; Keevil, B G.
Afiliação
  • Richardson G; Department of Clinical Biochemistry, University Hospital of South Manchester, Manchester Academic Health Science Centre, The University of Manchester, Manchester, UK.
  • Marshall D; Department of Clinical Biochemistry, University Hospital of South Manchester, Manchester Academic Health Science Centre, The University of Manchester, Manchester, UK.
  • Keevil BG; Department of Clinical Biochemistry, University Hospital of South Manchester, Manchester Academic Health Science Centre, The University of Manchester, Manchester, UK.
Ann Clin Biochem ; 55(3): 363-367, 2018 May.
Article em En | MEDLINE | ID: mdl-28774182
Background When preparing dried blood spots (DBSs), haematocrit (Hct) can affect the ability of the blood to spread through the filter paper, thus resulting in varying quantities of sample being measured when fixed subpunches of the DBSs are taken. It may be important to predict the sample Hct to correct volume differences. Methods Blood (10 µL) was applied to Perkin Elmer 226® paper. The samples ( n = 165) were allowed to dry for 24 h, and the entire blood spots were cut out. Subpunch analysis was also performed on blood spots prepared from 75 µL EDTA blood, taking 6 mm subpunches centrally and peripherally from the spots ( n = 59). The spots were eluted with 100 µL water, and a 10 µL aliquot of lysate was added to sulfolyser reagent (80 µL) in a microtitre plate. Hb was measured at 550 nm using an ELISA plate reader. DBS samples were compared against blood samples measured on a routine Sysmex XN-9000 analyser. Results The Passing and Bablock regression showed Hct (DBS-predicted) = 0.99 Hct (Sysmex) -0.02, R2 = 0.87. Intra-assay imprecision measured at Hct values of 0.27, 0.40 and 0.52, gave CVs of 4.1%, 2.8% and 4.2%, respectively. Inter-assay imprecision showed CVs of 6.2%, 5.2% and 4.2%, respectively. DBS samples were stable for up to two days at 60℃, one month at room temperature and six months at 4℃. Conclusion This method provides a simple and fast estimation of predicted Hct in dried blood spots.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dodecilsulfato de Sódio / Sangue / Hemoglobinas / Hematócrito Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dodecilsulfato de Sódio / Sangue / Hemoglobinas / Hematócrito Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article