Your browser doesn't support javascript.
loading
Study of Alzheimer's Disease-Related Biophysical Kinetics with a Microslit-Embedded Cantilever Sensor in a Liquid Environment.
Chae, Myung-Sic; Kim, Jinsik; Yoo, Yong Kyoung; Lee, Jeong Hoon; Kim, Tae Geun; Hwang, Kyo Seon.
Afiliação
  • Chae MS; Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul 02447, Korea. bechu88@gmail.com.
  • Kim J; School of Electrical Engineering, Korea University, Seoul 02841, Korea. bechu88@gmail.com.
  • Yoo YK; Department of Medical Biotechnology, College of Life Science and Biotechnology, Dongguk University, Seoul 10326, Korea. lookup2@dongguk.edu.
  • Lee JH; Department of Electrical Engineering, Kwangwoon University, Seoul 01897, Korea. yongkyoung0108@gmail.com.
  • Kim TG; Department of Electrical Engineering, Kwangwoon University, Seoul 01897, Korea. jhlee@kw.ac.kr.
  • Hwang KS; School of Electrical Engineering, Korea University, Seoul 02841, Korea. tgkim1@korea.ac.kr.
Sensors (Basel) ; 17(8)2017 Aug 07.
Article em En | MEDLINE | ID: mdl-28783132
ABSTRACT
A microsized slit-embedded cantilever sensor (slit cantilever) was fabricated and evaluated as a biosensing platform in a liquid environment. In order to minimize the degradation caused by viscous damping, a 300 × 100 µm² (length × width) sized cantilever was released by a 5 µm gap-surrounding and vibrated by an internal piezoelectric-driven self-actuator. Owing to the structure, when the single side of the slit cantilever was exposed to liquid a significant quality factor (Q = 35) could be achieved. To assess the sensing performance, the slit cantilever was exploited to study the biophysical kinetics related to Aß peptide. First, the quantification of Aß peptide with a concentration of 10 pg/mL to 1 µg/mL was performed. The resonant responses exhibited a dynamic range from 100 pg/mL to 100 ng/mL (-56.5 to -774 ΔHz) and a dissociation constant (KD) of binding affinity was calculated as 1.75 nM. Finally, the Aß self-aggregation associated with AD pathogenesis was monitored by adding monomeric Aß peptides. As the concentration of added analyte increased from 100 ng/mL to 10 µg/mL, both the frequency shift values (-813 to -1804 ΔHz) and associate time constant increased. These results showed the excellent sensing performance of the slit cantilever overcoming a major drawback in liquid environments to become a promising diagnostic tool candidate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença de Alzheimer Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença de Alzheimer Idioma: En Ano de publicação: 2017 Tipo de documento: Article