Your browser doesn't support javascript.
loading
Comparison of the moulding ability of Plaster of Paris and polyester cast material in the healthy adult forearm.
Bullen, Michael; Kinealy, John; Blanchard, Romane; Rodda, Christine; Pivonka, Peter.
Afiliação
  • Bullen M; Department of Surgery, Melbourne Medical School - Western Precinct, The University of Melbourne, St. Albans, VIC 3021, Australia; Western Health Outpatients Department, Western Health, Footscray, VIC, Australia. Electronic address: Michael.bullen@svha.org.au.
  • Kinealy J; Western Health Outpatients Department, Western Health, Footscray, VIC, Australia.
  • Blanchard R; St Vincent's Department of Surgery, University of Melbourne, Fitzroy, VIC, Australia; Australian Institute of Musculoskeletal Science, Sunshine Hospital, St. Albans, VIC, Australia.
  • Rodda C; Australian Institute of Musculoskeletal Science, Sunshine Hospital, St. Albans, VIC, Australia; Department of Paediatrics, University of Melbourne, Royal Children's Hospital, Parkville 3052, Australia; Melbourne Medical School - Western Precinct, The University of Melbourne, St. Albans, VIC 3021, Au
  • Pivonka P; St Vincent's Department of Surgery, University of Melbourne, Fitzroy, VIC, Australia; Australian Institute of Musculoskeletal Science, Sunshine Hospital, St. Albans, VIC, Australia.
Injury ; 48(11): 2586-2589, 2017 Nov.
Article em En | MEDLINE | ID: mdl-28870625
ABSTRACT

OBJECTIVES:

To quantify the moulding ability of Plaster of Paris and polyester cast materials as assessed by the novel use of peripheral quantitative computed tomography.

METHODS:

A prospective crossover study was performed in 25 healthy volunteers aged 18-65 years. Participants' non-dominant wrist was immobilized using a synthetic polyester cast followed by a Plaster of Paris cast with three point moulding to simulate reduction of a dorsally angulated distal radius fracture. The novel use of peripheral quantitative computed tomography was used to measure the closeness of fit of each cast on an axial tomographic slice. RESULTS AND

CONCLUSIONS:

Plaster of Paris casts were able to achieve a closer mould than polyester when measured between the bone and the cast (p=0.002), as well as between the skin and the cast (p=0.001). There was no difference when stratified on BMI. Using pQCT assessment, a closely moulded fit was able to be more consistently achieved when using Plaster of Paris when compared to polyester casts of the distal radius. LEVEL OF EVIDENCE III.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliésteres / Articulação do Punho / Sulfato de Cálcio / Moldes Cirúrgicos / Antebraço Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliésteres / Articulação do Punho / Sulfato de Cálcio / Moldes Cirúrgicos / Antebraço Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article