Your browser doesn't support javascript.
loading
A Reconfigurable Multiplanar In Vitro Simulator for Real-Time Absolute Motion With External and Musculotendon Forces.
Green, Joshua T; Hale, Rena F; Hausselle, Jerome; Gonzalez, Roger V.
Afiliação
  • Green JT; Mem. ASME Department of Metallurgical, Materials and Biomedical Engineering, College of Engineering, The University of Texas at El Paso, 500 West University Avenue, El Paso, TX 79968 e-mail: .
  • Hale RF; Orthopedic Biomechanics Laboratory, Mayo Clinic, 200 1st Street Southwest, Rochester, MN 55905 e-mail: .
  • Hausselle J; Mechanical and Aerospace Engineering, College of Engineering, Architecture and Technology, Oklahoma State University, 218 Engineering North, Stillwater, OK 74078 e-mail: .
  • Gonzalez RV; Mem. ASME Department of Engineering Education and Leadership, College of Engineering, The University of Texas at El Paso, 500 West University Avenue, El Paso, TX 79968 e-mail: .
J Biomech Eng ; 139(12)2017 Dec 01.
Article em En | MEDLINE | ID: mdl-28877307
ABSTRACT
Advancements in computational musculoskeletal biomechanics are constrained by a lack of experimental measurement under real-time physiological loading conditions. This paper presents the design, configuration, capabilities, accuracy, and repeatability of The University of Texas at El Paso Joint Load Simulator (UTJLS) by testing four cadaver knee specimens with 47 real-time tests including heel and toe squat maneuvers with and without musculotendon forces. The UTJLS is a musculoskeletal simulator consisting of two robotic manipulators and eight musculotendon actuators. Sensors include eight tension load cells, two force/torque systems, nine absolute encoders, and eight incremental encoders. A custom control system determines command output for position, force, and hybrid control and collects data at 2000 Hz. Controller configuration performed forward-dynamic control for all knee degrees-of-freedom (DOFs) except knee flexion. Actuator placement and specimen potting techniques uniquely replicate muscle paths. Accuracy and repeatability standard deviations across specimen during squat simulations were equal or less than 8 N and 5 N for musculotendon actuators, 30 N and 13 N for ground reaction forces (GRFs), and 4.4 N·m and 1.9 N·m for ground reaction moments. The UTJLS is the first of its design type. Controller flexibility and physical design support axis constraints to match traditional testing rigs, absolute motion, and synchronous real-time simulation of multiplanar kinematics, GRFs, and musculotendon forces. System DOFs, range of motion, and speed support future testing of faster maneuvers, various joints, and kinetic chains of two connected joints.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tendões / Fenômenos Mecânicos / Movimento / Músculos Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tendões / Fenômenos Mecânicos / Movimento / Músculos Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article