Your browser doesn't support javascript.
loading
A novel framework for evaluating the image accuracy of dynamic MRI and the application on accelerated breast DCE MRI.
Le, Yuan; Nickel, Marcel Dominik; Kannengiesser, Stephan; Kiefer, Berthold; Spottiswoode, Bruce; Dale, Brian; Soon, Victor; Lin, Chen.
Afiliação
  • Le Y; Department of Radiology and Imaging Science, Indiana University School of Medicine, 950 West Walnut St. R2 E124, Indianapolis, IN, 46202, USA.
  • Nickel MD; Siemens Healthcare, Erlangen, Germany.
  • Kannengiesser S; Siemens Healthcare, Erlangen, Germany.
  • Kiefer B; Siemens Healthcare, Erlangen, Germany.
  • Spottiswoode B; Siemens Medical Solutions USA Inc, Malven, PA, USA.
  • Dale B; Siemens Medical Solutions USA Inc, Malven, PA, USA.
  • Soon V; Department of Radiology and Imaging Science, Indiana University School of Medicine, 950 West Walnut St. R2 E124, Indianapolis, IN, 46202, USA.
  • Lin C; Department of Radiology and Imaging Science, Indiana University School of Medicine, 950 West Walnut St. R2 E124, Indianapolis, IN, 46202, USA. clin1@iupui.edu.
MAGMA ; 31(2): 309-320, 2018 Apr.
Article em En | MEDLINE | ID: mdl-28894997
OBJECTIVE: To develop a novel framework for evaluating the accuracy of quantitative analysis on dynamic contrast-enhanced (DCE) MRI with a specific combination of imaging technique, scanning parameters, and scanner and software performance and to test this framework with breast DCE MRI with Time-resolved angiography WIth Stochastic Trajectories (TWIST). MATERIALS AND METHODS: Realistic breast tumor phantoms were 3D printed as cavities and filled with solutions of MR contrast agent. Full k-space raw data of individual tumor phantoms and a uniform background phantom were acquired. DCE raw data were simulated by sorting the raw data according to TWIST view order and scaling the raw data according to the enhancement based on pharmaco-kinetic (PK) models. The measured spatial and temporal characteristics from the images reconstructed using the scanner software were compared with the original PK model (ground truth). RESULTS: Images could be reconstructed using the manufacturer's platform with the modified 'raw data.' Compared with the 'ground truth,' the RMS error in all images was <10% in most cases. With increasing view-sharing acceleration, the error of the initial uptake slope decreased while the error of peak enhancement increased. Deviations of PK parameters varied with the type of enhancement. CONCLUSION: A new framework has been developed and tested to more realistically evaluate the quantitative measurement errors caused by a combination of the imaging technique, parameters and scanner and software performance in DCE-MRI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Mama / Neoplasias da Mama / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Female / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Mama / Neoplasias da Mama / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Female / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article