Your browser doesn't support javascript.
loading
Characterizing endourologist learning curve during percutaneous nephrolithotomy: implications on occupational dose and patients.
Guiu-Souto, Jacobo; Otero-Martínez, Carlos; Pérez-Fentes, Daniel; Fernández-Baltar, Carlos; Sánchez-García, Juan F; García-Freire, Camilo; Pombar, Miguel; Pardo-Montero, Juan.
Afiliação
  • Guiu-Souto J; Department of Medical Physics, University Hospital of Santiago de Compostela, Santiago de Compostela, A Coruña, SPAIN.
  • Otero-Martínez C; Department of Medical Physics, University Hospital of Santiago de Compostela, Santiago de Compostela, A Coruña, SPAIN.
  • Pérez-Fentes D; Department of Urology, University Hospital of Santiago de Compostela, Santiago de Compostela, A Coruña, SPAIN.
  • Fernández-Baltar C; Department of Urology, University Hospital of Santiago de Compostela, Santiago de Compostela, A Coruña, SPAIN.
  • Sánchez-García JF; Department of Urology, University Hospital of Santiago de Compostela, Santiago de Compostela, A Coruña, SPAIN.
  • García-Freire C; Department of Urology, University Hospital of Santiago de Compostela, Santiago de Compostela, A Coruña, SPAIN.
  • Pombar M; Department of Medical Physics, Complejo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Galicia, SPAIN.
  • Pardo-Montero J; Instituto de Investigación Sanitaria de Santiago, Complexo Hospitalario Universitario de Santiago, E-15706 Santiago de Compostela, Santiago de Compostela, SPAIN.
J Radiol Prot ; 2017 Sep 22.
Article em En | MEDLINE | ID: mdl-28936986
ABSTRACT
In this study we have characterized the learning curve of percutaneous nephrolithotomy procedures over 301 cases for six years. Different surrogate parameters of clinical expertise have been used, such as dose area product, total procedure time, fluoroscopy time and personal equivalent doses. In addition, two different endourologists have been monitored; one of whom was subjected to a specific Radiation Protection training (ICRP 85). Eye lens dose is estimated from thermoluminescent dosimeters. Significant differences are observed between both endourologists, especially in the fluoroscopy time. Finally, both entrance skin dose and effective doses of patients have been determined.