BACKGROUND: The assessment of capillary refill time (CRT) is a common physical examination technique. However, despite its importance and its widespread use, there is little standardization, which can lead to inaccurate assessments. OBJECTIVE: In this article, we assessed how different physicians estimate CRT. We hypothesized that when different physicians are presented with the same recordings of CRT, clinicians will, on average, provide different CRT estimates. METHODS: Using recordings of different fingertip compressions, physicians assessed and documented when capillary refill had returned to normal. Videos were recorded of the fingertips only, with no other identifying markers or subject characteristics provided. Videos were shown at one-quarter speed to allow time for recognition and response to the capillary refill. The primary outcome was physician estimates of CRT for each video recording. RESULTS: An analysis of variance regression revealed significant differences in physician estimates of CRT when examining the same CRT videos from 34 subjects. Further regression analyses reveal the importance of controlling for the physician that is examining the patient when predicting a patient's CRT. CONCLUSIONS: Results indicate that some physicians gave, on average, slower CRT estimates, whereas others gave, on average, faster CRT estimates. Objective approaches and innovations in assessment of capillary refill have the potential to increase the diagnostic accuracy of this important clinical examination finding.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exame Físico / Fatores de Tempo / Capilares / Dedos Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exame Físico / Fatores de Tempo / Capilares / Dedos Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article