Your browser doesn't support javascript.
loading
Searching for assay controls for the Fpg- and hOGG1-modified comet assay.
Møller, Peter; Jantzen, Kim; Løhr, Mille; Andersen, Maria Helena; Jensen, Ditte Marie; Roursgaard, Martin; Danielsen, Pernille Høgh; Jensen, Annie; Loft, Steffen.
Afiliação
  • Møller P; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Jantzen K; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Løhr M; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Andersen MH; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Jensen DM; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Roursgaard M; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Danielsen PH; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Jensen A; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
  • Loft S; Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade, Copenhagen K, Denmark.
Mutagenesis ; 33(1): 9-19, 2018 02 24.
Article em En | MEDLINE | ID: mdl-28992346
ABSTRACT
The formamidopyrimidine DNA glycosylase (Fpg) and human 8-oxoguanine DNA glycosylase (hOGG1)-modified comet assays have been widely used in human biomonitoring studies. The purpose of this article is to assess differences in reported levels of Fpg- and hOGG1-sensitive sites in leukocytes and suggest suitable assay controls for the measurement of oxidatively damaged DNA. An assessment of the literature showed a large variation in the reported levels of Fpg-sensitive sites (range 0.05-1.31 lesions/106 bp). The levels of Fpg-sensitive sites are lower in studies where Fpg has been obtained from commercial suppliers or unknown sources as compared to Fpg from one particular non-commercial source (χ2 = 7.14, P = 0.028). The levels of hOGG1-sensitive sites are lower (range 0.04-0.18 lesions/106 bp in leukocytes) compared to the Fpg-sensitive sites. Surprisingly, few publications have reported the use of oxidising agents as assay controls, with the exception of hydrogen peroxide. This may be due to a lack of consensus about suitable controls for the Fpg- and hOGG1-modified comet assay. A major challenge is to find an oxidising agent that only oxidises nucleobases and does not generate DNA strand breaks because this reduces the dynamic range of Fpg- and hOGG1-sensitive sites in the comet assay. Based on a literature search we selected the photosensitiser Ro19-8022 plus light, KBrO3, 4-nitroquinoline-1-oxide, Na2Cr2O7 and ferric nitrilotriacetate as possible assay controls. A subsequent assessment of these compounds for generating cryopreserved assay controls in mononuclear blood cells showed that Ro19-8022 plus light, KBrO3 and 4-nitroquinoline-1-oxide provided suitable assay controls. We recommend these compounds as comet assay controls for oxidatively damaged DNA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio Cometa / DNA Glicosilases / DNA-Formamidopirimidina Glicosilase Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio Cometa / DNA Glicosilases / DNA-Formamidopirimidina Glicosilase Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article