The impact of imaging modality (CT vs MRI) and patient position (supine vs prone) on tangential whole breast radiation therapy planning.
Dundas, Kylie; Pogson, Elise M; Batumalai, Vikneswary; Delaney, Geoff P; Boxer, Miriam M; Yap, Mei Ling; Ahern, Verity; Chan, Christine; David, Steven; Dimigen, Marion; Harvey, Jennifer A; Koh, Eng-Siew; Lim, Karen; Papadatos, George; Lazarus, Elizabeth; Descellar, Joseph; Metcalfe, Peter; Holloway, Lois.
Afiliação
  • Dundas K; Centre for Medical Radiation Physics, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW, Australia; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Aust
  • Pogson EM; Centre for Medical Radiation Physics, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW, Australia; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Aust
  • Batumalai V; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia.
  • Delaney GP; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia; School of Medicine, University of Western
  • Boxer MM; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia.
  • Yap ML; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia; School of Medicine, University of Western
  • Ahern V; Crown Princess Mary Cancer Care Centre, Westmead Hospital, NSW, Australia.
  • Chan C; Department of Radiology, Liverpool Hospital, NSW, Australia.
  • David S; Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.
  • Dimigen M; Department of Radiology, Liverpool Hospital, NSW, Australia.
  • Harvey JA; School of Medicine, University of Queensland, QLD, Australia; Princess Alexandra Hospital, QLD, Australia.
  • Koh ES; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia.
  • Lim K; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia.
  • Papadatos G; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia.
  • Lazarus E; Department of Radiology, Liverpool Hospital, NSW, Australia.
  • Descellar J; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia.
  • Metcalfe P; Centre for Medical Radiation Physics, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW, Australia; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Aust
  • Holloway L; Centre for Medical Radiation Physics, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW, Australia; Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, Australia; Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW, Aust
Pract Radiat Oncol ; 8(3): e87-e97, 2018.
Article em En | MEDLINE | ID: mdl-28993138
ABSTRACT

PURPOSE:

The purpose of this study was to evaluate the impact of magnetic resonance imaging (MRI) versus computed tomography (CT)-derived planning target volumes (PTVs), in both supine and prone positions, for whole breast (WB) radiation therapy. METHODS AND MATERIALS Four WB radiation therapy plans were generated for 28 patients in which PTVs were generated based on CT or MRI data alone in both supine and prone positions. A 6-MV tangential intensity modulated radiation therapy technique was used, with plans designated as ideal, acceptable, or noncompliant. Dose metrics for PTVs and organs at risk were compared to analyze any differences based on imaging modality (CT vs MRI) or patient position (supine vs prone).

RESULTS:

With respect to imaging modality 2/11 whole breast planning target volume (WB_PTV) dose metrics (percentage of PTV receiving 90% and 110% of prescribed dose) displayed statistically significant differences; however, these differences did not alter the average plan compliance rank. With respect to patient positioning, the odds of having an ideal plan versus a noncompliant plan were higher for the supine position compared with the prone position (P = .026). The minimum distance between the seroma cavity planning target volume (SC_PTV) and the chest wall was increased with prone positioning (P < .001, supine and prone values 1.1 mm and 8.7 mm, respectively). Heart volume was greater in the supine position (P = .005). Heart doses were lower in the supine position than prone (P < .01, mean doses 3.4 ± 1.55 Gy vs 4.4 ± 1.13 Gy for supine vs prone, respectively). Mean lung doses met ideal dose constraints in both positions, but were best spared in the prone position. The contralateral breast maximum dose to 1cc (D1cc) showed significantly lower doses in the supine position (P < .001, 4.64 Gy vs 9.51 Gy).

CONCLUSIONS:

Planning with PTVs generated from MRI data showed no clinically significant differences from planning with PTVs generated from CT with respect to PTV and doses to organs at risk. Prone positioning within this study reduced mean lung dose and whole heart volumes but increased mean heart and contralateral breast doses compared with supine.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Posicionamento do Paciente Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Posicionamento do Paciente Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article