Your browser doesn't support javascript.
loading
Tailored intraoperative localization of non-palpable pulmonary lesions for thoracoscopic wedge resection using hybrid room technology.
Stanzi, Alessia; Mazza, Federico; Lucio, Francesco; Ghirardo, Donatella; Grosso, Maurizio; Locatelli, Alessandro; Melloni, Giulio.
Afiliação
  • Stanzi A; Department of Thoracic Surgery, Santa Croce e Carle General Hospital, Cuneo, Italy.
  • Mazza F; Department of Thoracic Surgery, Santa Croce e Carle General Hospital, Cuneo, Italy.
  • Lucio F; Medical Physics Department, Santa Croce e Carle General Hospital, Cuneo, Italy.
  • Ghirardo D; Department of Radiology, Santa Croce e Carle General Hospital, Cuneo, Italy.
  • Grosso M; Department of Radiology, Santa Croce e Carle General Hospital, Cuneo, Italy.
  • Locatelli A; Department of Anesthesia and Intensive Care, Santa Croce e Carle General Hospital, Cuneo, Italy.
  • Melloni G; Department of Thoracic Surgery, Santa Croce e Carle General Hospital, Cuneo, Italy.
Clin Respir J ; 12(4): 1661-1667, 2018 Apr.
Article em En | MEDLINE | ID: mdl-29028153
INTRODUCTION: VATS wedge resection can require conversion to thoracotomy when pulmonary lesions cannot be identified. Hybrid operating rooms (HORs) provide real-time image acquisition capabilities allowing the intraoperative placement of markers to facilitate the removal of non-palpable nodules during VATS. OBJECTIVES: To present our workflow based on the alternative use of two different markers according to the location of the lung lesion and report our initial results. METHODS: All consecutive patients with non-palpable lesions requiring VATS wedge resection underwent localization of the targets in HOR. Lesions were considered non-palpable if they were small (<1 cm), deep (>1 cm from surface), subsolid, or located within a dystrophic area. Anesthetized patients were placed in lateral decubitus. Cone-beam CT (CBCT) was performed, and the needle trajectory was planned using Syngo iGuide Needle Guidance. Metal hook-wire or coil was placed, according to our workflow, close to the lesion and their position was verified by CBCT or fluoroscopy. RESULTS: Eleven VATS wedge resections were performed in 10 patients with 12 non-palpable lesions. The localization was performed with seven hook-wires and four coils in 30 minutes (range 17-56 minutes). The median estimated total effective dose was 11.6 mSv (range 1.9-24.7 mSv). Eleven lesions were removed by VATS, and one deep nodule required a thoracotomy. No complications were observed. CONCLUSIONS: Our experience confirms that HOR is suitable for simultaneous localization and VATS resection of 'difficult' pulmonary lesions. A versatile approach, using different devices, seems advisable for the removal of targets in every clinical scenario, reducing the VATS conversion rate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Salas Cirúrgicas / Pneumonectomia / Nódulo Pulmonar Solitário / Cirurgia Torácica Vídeoassistida / Posicionamento do Paciente / Pulmão / Neoplasias Pulmonares Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Salas Cirúrgicas / Pneumonectomia / Nódulo Pulmonar Solitário / Cirurgia Torácica Vídeoassistida / Posicionamento do Paciente / Pulmão / Neoplasias Pulmonares Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article