Your browser doesn't support javascript.
loading
Image artifacts and noise reduction algorithm for cone-beam computed tomography with low-signal projections.
Yang, Fu-Qiang; Zhang, Ding-Hua; Huang, Kui-Dong; Yang, Ya-Fei; Liao, Jin-Ming.
Afiliação
  • Yang FQ; Key Lab of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi'an, China.
  • Zhang DH; Key Lab of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi'an, China.
  • Huang KD; Key Lab of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi'an, China.
  • Yang YF; Key Lab of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi'an, China.
  • Liao JM; Key Lab of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi'an, China.
J Xray Sci Technol ; 26(2): 227-240, 2018.
Article em En | MEDLINE | ID: mdl-29036876
ABSTRACT
This study aims to investigate and test a new image reconstruction algorithm applying to the low-signal projections to generate high quality images by reducing the artifacts and noise in the cone-beam computed tomography (CBCT). For the low-signal and noisy projections, a multiple sampling method is first utilized in projection domain to suppress environmental noise, which guarantees the accuracy of the data for reconstruction, simultaneously. Next, a fuzzy entropy based method with block matching 3D (BM3D) filtering algorithm is employed to improve the image quality to reduce artifacts and noise in image domain. Then, simulation studies on polychromatic spectrum were performed to evaluate the performance of the proposed new algorithm. Study results demonstrated significant improvement in the signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of the images reconstructed using the new algorithm. SNRs and CNRs of the new images were averagely 40% and 20% higher than those of the previous images reconstructed using the traditional algorithms, respectively. As a result, since the new image reconstruction algorithm effectively reduced the artifacts and noise, and produced images with better contour and grayscale distribution, it has the potential to improve image quality using the original CBCT data with the low and missing signals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Artefatos / Imageamento Tridimensional / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Artefatos / Imageamento Tridimensional / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article