Evaluation of Sensible Heat Flux and Evapotranspiration Estimates Using a Surface Layer Scintillometer and a Large Weighing Lysimeter.
Moorhead, Jerry E; Marek, Gary W; Colaizzi, Paul D; Gowda, Prasanna H; Evett, Steven R; Brauer, David K; Marek, Thomas H; Porter, Dana O.
Afiliação
  • Moorhead JE; USDA-ARS Conservation and Production Research Laboratory, PO Drawer 10, Bushland, TX 79012, USA. jed.moorhead@ars.usda.gov.
  • Marek GW; USDA-ARS Conservation and Production Research Laboratory, PO Drawer 10, Bushland, TX 79012, USA. gary.marek@ars.usda.gov.
  • Colaizzi PD; USDA-ARS Conservation and Production Research Laboratory, PO Drawer 10, Bushland, TX 79012, USA. paul.colaizzi@ars.usda.gov.
  • Gowda PH; USDA-ARS Grazinglands Research Laboratory, 7207 West Cheyenne St., El Reno, OK 73036, USA. prasanna.gowda@ars.usda.gov.
  • Evett SR; USDA-ARS Conservation and Production Research Laboratory, PO Drawer 10, Bushland, TX 79012, USA. steve.evett@ars.usda.gov.
  • Brauer DK; USDA-ARS Conservation and Production Research Laboratory, PO Drawer 10, Bushland, TX 79012, USA. david.brauer@ars.usda.gov.
  • Marek TH; Texas A&M AgriLife Research, 6500 Amarillo Blvd W, Amarillo, TX 79106, USA. tmarek@ag.tamu.edu.
  • Porter DO; Texas A&M AgriLife Extension Service, 1102 E FM 1294, Lubbock, TX 79403, USA. dporter@ag.tamu.edu.
Sensors (Basel) ; 17(10)2017 Oct 14.
Article em En | MEDLINE | ID: mdl-29036926
ABSTRACT
Accurate estimates of actual crop evapotranspiration (ET) are important for optimal irrigation water management, especially in arid and semi-arid regions. Common ET sensing methods include Bowen Ratio, Eddy Covariance (EC), and scintillometers. Large weighing lysimeters are considered the ultimate standard for measurement of ET, however, they are expensive to install and maintain. Although EC and scintillometers are less costly and relatively portable, EC has known energy balance closure discrepancies. Previous scintillometer studies used EC for ground-truthing, but no studies considered weighing lysimeters. In this study, a Surface Layer Scintillometer (SLS) was evaluated for accuracy in determining ET as well as sensible and latent heat fluxes, as compared to a large weighing lysimeter in Bushland, TX. The SLS was installed over irrigated grain sorghum (Sorghum bicolor (L.) Moench) for the period 29 July-17 August 2015 and over grain corn (Zea mays L.) for the period 23 June-2 October 2016. Results showed poor correlation for sensible heat flux, but much better correlation with ET, with r² values of 0.83 and 0.87 for hourly and daily ET, respectively. The accuracy of the SLS was comparable to other ET sensing instruments with an RMSE of 0.13 mm·h-1 (31%) for hourly ET; however, summing hourly values to a daily time step reduced the ET error to 14% (0.75 mm·d-1). This level of accuracy indicates that potential exists for the SLS to be used in some water management applications. As few studies have been conducted to evaluate the SLS for ET estimation, or in combination with lysimetric data, further evaluations would be beneficial to investigate the applicability of the SLS in water resources management.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article