Your browser doesn't support javascript.
loading
Comminuted inferior pole fracture of patella can be successfully treated with rim-plate-augmented separate vertical wiring.
Cho, Jae-Woo; Kim, Jinil; Cho, Won-Tae; Gujjar, Pranay H; Oh, Chang-Wug; Oh, Jong-Keon.
Afiliação
  • Cho JW; Department of Orthopedic Surgery, Guro Hospital, Korea University Medical Center, 148, Gurodong-ro, Guro-gu, 152-703, Seoul, Korea.
  • Kim J; Department of Orthopedic Surgery, Wonju Severance Christian Hospital, Wonju, Korea.
  • Cho WT; Department of Orthopedic Surgery, Guro Hospital, Korea University Medical Center, 148, Gurodong-ro, Guro-gu, 152-703, Seoul, Korea.
  • Gujjar PH; Department of Orthopedic Surgery, Guro Hospital, Korea University Medical Center, 148, Gurodong-ro, Guro-gu, 152-703, Seoul, Korea.
  • Oh CW; Department of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, Korea.
  • Oh JK; Department of Orthopedic Surgery, Guro Hospital, Korea University Medical Center, 148, Gurodong-ro, Guro-gu, 152-703, Seoul, Korea. jkoh@korea.ac.kr.
Arch Orthop Trauma Surg ; 138(2): 195-202, 2018 Feb.
Article em En | MEDLINE | ID: mdl-29058078
INTRODUCTION: We present the surgical technique of rim-plate-augmented separate vertical wiring for comminuted inferior pole fracture of the patella and report the clinical outcomes. MATERIALS AND METHODS: Between July 2013 and January 2016, 13 patients (7 male and 6 female) who were diagnosed with comminuted inferior pole fracture of the patella in preoperative computed tomography and underwent a minimum of 1 year of follow-up were enrolled in this study. Mean patient age was 57.7 years (range 28-72 years). All patients underwent open reduction and internal fixation by rim-plate-augmented separate vertical wiring. Bony union, complications, range of motion and Bostman score were the clinical outcomes. RESULTS: Bony union was achieved in all cases at an average of 10 weeks after surgery (range 8-12). There was no loss of reduction and fixative failure during follow-up. The average range of motion was 127° (range 120°-130°). The mean Bostman score at last follow-up was 29.6 points (range 27-30) and graded excellent in 12 patients. CONCLUSION: Rim-plate-augmented separate vertical wiring demonstrated secure fixation and favorable clinical outcomes. This study provides evidence for its effectiveness as a fixation method for treating displaced, comminuted inferior pole fracture of the patella.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patela / Fios Ortopédicos / Fraturas Cominutivas / Fixação Interna de Fraturas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patela / Fios Ortopédicos / Fraturas Cominutivas / Fixação Interna de Fraturas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article