Significant Drop in Right Atrial Pressure Does Not Influence Fractional Flow Reserve Coronary Assessment.
J Heart Valve Dis
; 26(3): 361-364, 2017 05.
Article
em En
| MEDLINE
| ID: mdl-29092125
The effect of a highly elevated level of right atrial filling pressure on fractional flow reserve (FFR) measurement remains unclear. Transcatheter tricuspid valve intervention, a recently introduced option for inoperable or high-risk patients, represents a unique model of in-vivo physiology to investigate the eventual influence of central venous pressure on coronary FFR measurements. The case is reported of a patient with a degenerated tricuspid surgical bioprosthesis who underwent transcatheter tricuspid valve-in-valve replacement and concomitant coronary functional assessment with FFR. In an experimental model, the significant fall in right atrial pressure did not influence FFR measurements in the presence of angiographically proven mild coronary artery disease.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Valva Tricúspide
/
Insuficiência da Valva Tricúspide
/
Estenose da Valva Tricúspide
/
Função do Átrio Direito
/
Implante de Prótese de Valva Cardíaca
/
Reserva Fracionada de Fluxo Miocárdico
/
Pressão Atrial
Tipo de estudo:
Etiology_studies
/
Prognostic_studies
Limite:
Female
/
Humans
/
Middle aged
Idioma:
En
Ano de publicação:
2017
Tipo de documento:
Article