Your browser doesn't support javascript.
loading
Fast decomposition of two ultrasound longitudinal waves in cancellous bone using a phase rotation parameter for bone quality assessment: Simulation study.
Taki, Hirofumi; Nagatani, Yoshiki; Matsukawa, Mami; Kanai, Hiroshi; Izumi, Shin-Ichi.
Afiliação
  • Taki H; Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8575, Japan.
  • Nagatani Y; Department of Electronics, Kobe City College of Technology, Kobe 651-2194, Japan.
  • Matsukawa M; Faculty of Science and Engineering, Doshisha University, Kyotanabe 610-0321, Japan.
  • Kanai H; Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan.
  • Izumi SI; Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8575, Japan.
J Acoust Soc Am ; 142(4): 2322, 2017 10.
Article em En | MEDLINE | ID: mdl-29092537
ABSTRACT
Ultrasound signals that pass through cancellous bone may be considered to consist of two longitudinal waves, which are called fast and slow waves. Accurate decomposition of these fast and slow waves is considered to be highly beneficial in determination of the characteristics of cancellous bone. In the present study, a fast decomposition method using a wave transfer function with a phase rotation parameter was applied to received signals that have passed through bovine bone specimens with various bone volume to total volume (BV/TV) ratios in a simulation study, where the elastic finite-difference time-domain method is used and the ultrasound wave propagated parallel to the bone axes. The proposed method succeeded to decompose both fast and slow waves accurately; the normalized residual intensity was less than -19.5 dB when the specimen thickness ranged from 4 to 7 mm and the BV/TV value ranged from 0.144 to 0.226. There was a strong relationship between the phase rotation value and the BV/TV value. The ratio of the peak envelope amplitude of the decomposed fast wave to that of the slow wave increased monotonically with increasing BV/TV ratio, indicating the high performance of the proposed method in estimation of the BV/TV value in cancellous bone.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteogênese / Simulação por Computador / Ultrassonografia / Ondas Ultrassônicas / Osso Esponjoso / Modelos Teóricos Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteogênese / Simulação por Computador / Ultrassonografia / Ondas Ultrassônicas / Osso Esponjoso / Modelos Teóricos Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article