Your browser doesn't support javascript.
loading
A Water-Stable Luminescent ZnII Metal-Organic Framework as Chemosensor for High-Efficiency Detection of CrVI -Anions (Cr2 O72- and CrO42- ) in Aqueous Solution.
Yao, Zhao-Quan; Li, Guang-Yu; Xu, Jian; Hu, Tong-Liang; Bu, Xian-He.
Afiliação
  • Yao ZQ; School of Materials Science and Engineering, National Institute for Advanced Materials, Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin, 300350, P. R. China.
  • Li GY; School of Materials Science and Engineering, National Institute for Advanced Materials, Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin, 300350, P. R. China.
  • Xu J; School of Materials Science and Engineering, National Institute for Advanced Materials, Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin, 300350, P. R. China.
  • Hu TL; School of Materials Science and Engineering, National Institute for Advanced Materials, Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin, 300350, P. R. China.
  • Bu XH; Key Laboratory of Advanced Energy Materials Chemistry, (Ministry of Education), Collaborative Innovation Center of Chemical Science and Engineering (Tianjin), Tianjin, 300071, P. R. China.
Chemistry ; 24(13): 3192-3198, 2018 Mar 02.
Article em En | MEDLINE | ID: mdl-29210125
ABSTRACT
A new luminescent ZnII -MOF with 1D triangular channels along the b axis, namely NUM-5, has been successfully assembled and well characterized, which features good stability, especially in aqueous solution. Interestingly, this compound exhibits a fast, sensitive and selective luminescence quenching response towards CrVI (Cr2 O72- /CrO42- ) in aqueous solution. The detection limits towards Cr2 O72- and CrO42- ions are estimated to be 0.7 and 0.3 ppm, respectively, which are among the lowest detection limits reported for the MOF-based fluorescent probes that can simultaneously detect Cr2 O72- and CrO42- in aqueous environment. The possible detection mechanism has been discussed in detail. Moreover, it can be easily regenerated after detection experiments, indicative of excellent recyclability. All these results suggest NUM-5 to be a highly selective and recyclable luminescent sensing material for the quantitative detection of CrVI anions in aqueous solution.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article