Assessment of quantification accuracy and image quality of a full-body dual-layer spectral CT system.
Ehn, Sebastian; Sellerer, Thorsten; Muenzel, Daniela; Fingerle, Alexander A; Kopp, Felix; Duda, Manuela; Mei, Kai; Renger, Bernhard; Herzen, Julia; Dangelmaier, Julia; Schwaiger, Benedikt J; Sauter, Andreas; Riederer, Isabelle; Renz, Martin; Braren, Rickmer; Rummeny, Ernst J; Pfeiffer, Franz; Noël, Peter B.
Afiliação
  • Ehn S; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, Garching, Germany.
  • Sellerer T; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, Garching, Germany.
  • Muenzel D; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Fingerle AA; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Kopp F; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Duda M; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, Garching, Germany.
  • Mei K; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Renger B; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Herzen J; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, Garching, Germany.
  • Dangelmaier J; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Schwaiger BJ; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Sauter A; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Riederer I; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Renz M; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Braren R; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Rummeny EJ; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Pfeiffer F; Department of diagnostic and interventional Radiology, Technical University of Munich, Munich, Germany.
  • Noël PB; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, Garching, Germany.
J Appl Clin Med Phys ; 19(1): 204-217, 2018 Jan.
Article em En | MEDLINE | ID: mdl-29266724

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Proteção Radiológica / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Imagens de Fantasmas / Imagem Corporal Total Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Proteção Radiológica / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Imagens de Fantasmas / Imagem Corporal Total Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article