Your browser doesn't support javascript.
loading
Indoor exposure to particles emitted by biomass-burning heating systems and evaluation of dose and lung cancer risk received by population.
Stabile, L; Buonanno, G; Avino, P; Frattolillo, A; Guerriero, E.
Afiliação
  • Stabile L; Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino FR, Italy. Electronic address: l.stabile@unicas.it.
  • Buonanno G; Department of Engineering, University "Parthenope", Naples, Italy; Queensland University of Technology, Brisbane, Australia; Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino FR, Italy.
  • Avino P; D.I.P.I.A., INAIL Settore Ricerca, via Urbana 167, I-00184 Rome, Italy; DIAAA, University of Molise, Via de Sanctis, Campobasso, Italy.
  • Frattolillo A; Department of Civil and Environmental Engineering and Architecture, University of Cagliari, via Marengo 2, 09123 Cagliari, Italy.
  • Guerriero E; Institute of Atmospheric Pollution Research, National Research Council, Rome Research Area-Montelibretti, Monterotondo Scalo, Italy.
Environ Pollut ; 235: 65-73, 2018 Apr.
Article em En | MEDLINE | ID: mdl-29274539
ABSTRACT
Homes represent a critical microenvironment in terms of air quality due to the proximity to main particle sources and the lack of proper ventilation systems. Biomass-fed heating systems are still extensively used worldwide, then likely emitting a significant amount of particles in indoor environments. Nonetheless, research on biomass emissions are limited to their effects on outdoor air quality then not properly investigating the emission in indoor environments. To this purpose, the present paper aims to evaluate the exposure to different airborne particle metrics (including both sub- and super-micron particles) and attached carcinogenic compounds in dwellings where three different heating systems were used open fireplaces, closed fireplaces and pellet stoves. Measurements in terms of particle number, lung-deposited surface area, and PM fraction concentrations were measured during the biomass combustion activities, moreover, PM10 samples were collected and chemically analyzed to obtain mass fractions of carcinogenic compounds attached onto particles. Airborne particle doses received by people exposed in such environments were evaluated as well as their excess lung cancer risk. Most probable surface area extra-doses received by people exposed to open fireplaces on hourly basis (56 mm2 h-1) resulted one order of magnitude larger than those experienced for exposure to closed fireplaces and pellet stoves. Lifetime extra risk of Italian people exposed to the heating systems under investigation were larger than the acceptable lifetime risk (10-5) in particular, the risk due to the open fireplace (8.8 × 10-3) was non-negligible when compared to the overall lung cancer risk of typical Italian population.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos / Exposição Ambiental / Calefação / Neoplasias Pulmonares Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos / Exposição Ambiental / Calefação / Neoplasias Pulmonares Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article