Agreement between Pentacam and optical coherence tomography in the assessment of iridocorneal angle width in a large healthy population.
Fernández-Vigo, J I; De-Pablo-Gómez-de-Liaño, L; Almorín-Fernández-Vigo, I; Fernández-Vigo, C; Macarro-Merino, A; García-Feijóo, J; Fernández-Vigo, J Á.
Afiliação
  • Fernández-Vigo JI; Ophthalmology department, hospital universitario clínico San-Carlos, instituto de investigación sanitaria del hospital clínico San-Carlos (IdISSC), Madrid, Spain; Centro internacional de oftalmología Avanzada, Madrid, Spain. Electronic address: jfvigo@hotmail.com.
  • De-Pablo-Gómez-de-Liaño L; Centro internacional de oftalmología Avanzada, Madrid, Spain; Ophthalmology department, hospital universitario 12 de Octubre. Madrid, Spain.
  • Almorín-Fernández-Vigo I; Centro internacional de oftalmología Avanzada, Madrid, Spain.
  • Fernández-Vigo C; Centro internacional de oftalmología Avanzada, Madrid, Spain.
  • Macarro-Merino A; Centro internacional de oftalmología Avanzada, Madrid, Spain.
  • García-Feijóo J; Ophthalmology department, hospital universitario clínico San-Carlos, instituto de investigación sanitaria del hospital clínico San-Carlos (IdISSC), Madrid, Spain.
  • Fernández-Vigo JÁ; Centro internacional de oftalmología Avanzada, Madrid, Spain; Ophthalmology department, facultad de medicina, universidad de Extremadura, Badajoz, Spain.
J Fr Ophtalmol ; 41(1): 14-20, 2018 Jan.
Article em En | MEDLINE | ID: mdl-29295793
PURPOSE: To analyze the agreement between Pentacam and optical coherence tomography (OCT) in the assessment of trabecular-iris angle (TIA) width in a large population of normal subjects. METHODS: A cross-sectional study was performed in 989 right eyes of 989 healthy subjects. The trabecular-iris angle (TIA) was measured in the temporal and nasal quadrants using the Pentacam (Oculus, Wetzlar, Germany), a device based on Scheimpflug technology and RTVue 100 OCT (Optovue, Fremont, CA, USA). Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to evaluate agreement between these devices. RESULTS: Mean age was 49.1±15.2 years (18-84); 61% were women and spherical error range was -14 to 8.25. TIA could be measured by OCT in 94.9% and 94.1% in the temporal and nasal quadrants, with a mean value of 35.8±13.2 degrees (2.5-78.7) and 35.7±12.9 degrees (2.2-76.8) respectively. TIA was able to be measured by Pentacam in 95.2% and 95% in the temporal and nasal quadrants and means were 35.7±7.3 degrees (11-74.2) and 36.4±8.2 degrees (14.5-64) respectively. An ICC of 0.378 (95% confidence interval [CI], 0.322-0.431) and 0.589 (95% CI 0.546-0.629) for the temporal and nasal quadrants was obtained, showing moderate agreement between the devices. Bland-Altman plots revealed that, compared with OCT, Pentacam tends to overestimate measurements in narrow angles and underestimate these in open angles. CONCLUSIONS: Agreement between OCT and Pentacam was mediocre, indicating the two devices are not interchangeable when used to measure angle width.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malha Trabecular / Iris / Tomografia de Coerência Óptica / Técnicas de Diagnóstico Oftalmológico / Câmara Anterior Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malha Trabecular / Iris / Tomografia de Coerência Óptica / Técnicas de Diagnóstico Oftalmológico / Câmara Anterior Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article