Your browser doesn't support javascript.
loading
Signal enhancement ratio imaging of the lung parenchyma with ultra-fast steady-state free precession MRI at 1.5T.
Pusterla, Orso; Sommer, Gregor; Santini, Francesco; Wiese, Mark; Lardinois, Didier; Tamm, Michael; Bremerich, Jens; Bauman, Grzegorz; Bieri, Oliver.
Afiliação
  • Pusterla O; Division of Radiological Physics, Department of Radiology, University Hospital of Basel, Basel, Switzerland.
  • Sommer G; Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
  • Santini F; Clinic of Radiology and Nuclear Medicine, Cardiac and Thoracic Imaging, University Hospital of Basel, Basel, Switzerland.
  • Wiese M; Division of Radiological Physics, Department of Radiology, University Hospital of Basel, Basel, Switzerland.
  • Lardinois D; Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
  • Tamm M; Clinic of Thoracic Surgery, University Hospital of Basel, Basel, Switzerland.
  • Bremerich J; Clinic of Thoracic Surgery, University Hospital of Basel, Basel, Switzerland.
  • Bauman G; Clinic of Pneumology, University Hospital of Basel, Basel, Switzerland.
  • Bieri O; Clinic of Radiology and Nuclear Medicine, Cardiac and Thoracic Imaging, University Hospital of Basel, Basel, Switzerland.
J Magn Reson Imaging ; 48(1): 48-57, 2018 07.
Article em En | MEDLINE | ID: mdl-29297607
BACKGROUND: Lung perfusion MRI after i.v. gadolinium (Gd) contrast administration is commonly based on spoiled gradient-echo acquisitions, such as volume-interpolated breath-hold examinations (VIBE), suffering from low signal-to-noise in the parenchyma. PURPOSE: To investigate the lung signal enhancement ratio (SER) with ultra-fast steady-state free precession (ufSSFP) after Gd-administration. STUDY TYPE: Retrospective. SUBJECTS: Ten subjects with healthy lungs; nine patients with pulmonary diseases (chronic obstructive pulmonary disease [COPD], lung cancer, pulmonary fibrosis, lung contusion). FIELD STRENGTH/SEQUENCE: VIBE and ufSSFP imaging of the chest was performed at 1.5T before and 3 minutes after i.v. gadobenate dimeglumine. ASSESSMENT: A workflow including deformable image registration and median filtering was used to compute 3D SER maps. SER was analyzed in the lung, blood pool, liver, muscles, and fat. The artifacts were assessed by a radiologist. In the COPD patients, ufSSFP-SER was compared to 99m Tc-MAA-SPECT/CT by visual scoring of lung enhancement deficits. STATISTICAL TESTS: Mean signal, standard deviation (SD), intersubject SD, and coefficient of variation (CV) were calculated for SER. Statistical significance of differences in signal and artifacts were determined using Wilcoxon signed-rank paired test. Intermodality agreement between ufSSFP-SER and SPECT/CT was calculated by Cohen's kappa (κq ). RESULTS: In healthy lungs, ufSSFP-SER (99% ± 23%, mean ± pooled intrasubject SD, CV = 23%) was significantly higher (P < 10-3 ) and more homogeneous (P < 10-3 ) than VIBE (47% ± 26%, CV = 57%). UfSSFP-SER was significantly higher (P < 10-3 ) for the lungs (99% ± 9%, mean ± intersubject SD) than for the blood (81% ± 7%) and other tissues (liver 33% ± 8%, muscle 26% ± 5%, fat 2% ± 1%). In the lung ufSSFP-SER exhibits homogeneity on iso-gravitational planes, and an anterior-posterior gradient. In COPD patients, ufSSFP-SER was reduced and less homogeneous compared to the control group (73% ± 33%, mean ± pooled intrasubject SD, CV = 42%). ufSSFP-SER had moderate intermodality agreement with SPECT/CT (κq = 0.64). DATA CONCLUSION: UfSSFP-SER of the lung is a rapid and simple method. Our preliminary data show plausible results in different pulmonary diseases, motivating further evaluation in larger cohorts. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Gadolínio / Pulmão Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Gadolínio / Pulmão Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article