Your browser doesn't support javascript.
loading
Usefulness of live/real time three/four-dimensional transesophageal echocardiography in the percutaneous closure of an iatrogenic aorto-right ventricular fistula.
Kemaloglu Öz, Tugba; Fiore, Corrado; Gürol, Tayfun; Sener, Tufan; Soylu, Özer; Dagdeviren, Bahadir; Ahmad, Amier; Nanda, Navin C.
Afiliação
  • Kemaloglu Öz T; Department of Cardiology, Faculty of Medicine, Bahcesehir University, Istanbul, Turkey.
  • Fiore C; Department of Cardiology, Citta di Lecce Hospital GVM Care and Research, Lecce, Italy.
  • Gürol T; Department of Cardiology, Faculty of Medicine, Bahcesehir University, Istanbul, Turkey.
  • Sener T; Department of Cardiovascular Surgery, Gostepe Medical Park Hospital, Istanbul, Turkey.
  • Soylu Ö; Department of Cardiology, Faculty of Medicine, Bahcesehir University, Istanbul, Turkey.
  • Dagdeviren B; Department of Cardiology, Faculty of Medicine, Bahcesehir University, Istanbul, Turkey.
  • Ahmad A; Division of Internal Medicine, University of Alabama at Birmingham, Birmingham, AL, USA.
  • Nanda NC; Division of Cardiovascular Disease, University of Alabama at Birmingham, Birmingham, AL, USA.
Echocardiography ; 35(3): 410-412, 2018 03.
Article em En | MEDLINE | ID: mdl-29346704
The development of an aorto-right ventricular fistula is a rare complication of cardiac surgery. The most common treatment is surgical closure of the fistula, but percutaneous closure of the fistula has become an attractive alternative option. We present a case of successful utilization of live/real time three/four-dimensional transoesophageal echocardiography (3/4DTEE) to select the correct device size for percutaneous closure of an adult patient presenting with an aorto-right ventricular (AO-RV) fistula following aortic valve replacement. To the best of our knowledge, this is the first case in which 3/4DTEE was used to select the device size and guide percutaneous closure of an iatrogenic AO-RV fistula.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Fístula Vascular / Ecocardiografia Transesofagiana / Ecocardiografia Tridimensional / Ventrículos do Coração Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Fístula Vascular / Ecocardiografia Transesofagiana / Ecocardiografia Tridimensional / Ventrículos do Coração Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article