Your browser doesn't support javascript.
loading
[The Measurement Precision and Accuracy of T1 Mapping Using Polarity Corrected (PC) TI Prep Tool].
Ishikawa, Hironobu; Seino, Shinya; Takasumi, Hideaki; Kikori, Katsuyuki; Harata, Masahiro; Kanezawa, Takashi; Watanabe, Naoki; Satou, Takanori; Nishina, Takashi; Kuhara, Shigehide.
Afiliação
  • Ishikawa H; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Seino S; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Takasumi H; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Kikori K; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Harata M; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Kanezawa T; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Watanabe N; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Satou T; Department of Radiology, Public University Corporation Fukushima Medical University.
  • Nishina T; Toshiba Medical Systems Corporation.
  • Kuhara S; Department of Medical Radiological Technology in the Faculty of Health Sciences Kyorin University.
Article em Ja | MEDLINE | ID: mdl-29353832
The aim of this study was to evaluate the measurement precision and accuracy of T1 mapping using a polarity corrected (PC) TI prep tool, which was based on fast field echo (FFE) and obtained one data point with one inversion recovery (IR) pulse. A phantom was used consisting of eight materials with different Gd concentrations. T1 mappings were measured by changing the trigger interval and the inversion time (TI) interval. The T1 mapping measurement precision using the PC TI prep tool increased as the trigger interval was made longer. The measurement precision didn't depend on the interval of TI. On the other hand, when the trigger intervals are more than 1000 ms, the measurement accuracy was less than approximately 8%. By setting the optimal end of TI, the T1 mapping using a PC TI prep tool could measure the T1 value precisely and accurately.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética Idioma: Ja Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética Idioma: Ja Ano de publicação: 2018 Tipo de documento: Article