Your browser doesn't support javascript.
loading
Multi-compartmental diffusion characterization of the human cervical spinal cord in vivo using the spherical mean technique.
By, Samantha; Xu, Junzhong; Box, Bailey A; Bagnato, Francesca R; Smith, Seth A.
Afiliação
  • By S; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
  • Xu J; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
  • Box BA; Philips Healthcare, Gainesville, FL, USA.
  • Bagnato FR; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
  • Smith SA; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
NMR Biomed ; 31(4): e3894, 2018 04.
Article em En | MEDLINE | ID: mdl-29388719
ABSTRACT
The purpose of this work was to evaluate the feasibility and reproducibility of the spherical mean technique (SMT), a multi-compartmental diffusion model, in the spinal cord of healthy controls, and to assess its ability to improve spinal cord characterization in multiple sclerosis (MS) patients at 3 T. SMT was applied in the cervical spinal cord of eight controls and six relapsing-remitting MS patients. SMT provides an elegant framework to model the apparent axonal volume fraction vax , intrinsic diffusivity Dax , and extra-axonal transverse diffusivity Dex_perp (which is estimated as a function of vax and Dax ) without confounds related to complex fiber orientation distribution that reside in diffusion MRI modeling. SMT's reproducibility was assessed with two different scans within a month, and SMT-derived indices in healthy and MS cohorts were compared. The influence of acquisition scheme on SMT was also evaluated. SMT's vax , Dax , and Dex_perp measurements all showed high reproducibility. A decrease in vax was observed at the site of lesions and normal appearing white matter (p < 0.05), and trends towards a decreased Dax and increased Dex_perp were seen. Importantly, a twofold reduction in acquisition yielded similarly high accuracy with SMT. SMT provides a fast, reproducible, and accurate method to improve characterization of the cervical spinal cord, and may have clinical potential for MS patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem de Difusão por Ressonância Magnética / Medula Cervical Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem de Difusão por Ressonância Magnética / Medula Cervical Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article