Your browser doesn't support javascript.
loading
Exchange over the guidewire from non-tunneled to tunneled hemodialysis catheters can be performed without patency loss.
Park, Hoon Suk; Choi, Joonsung; Kim, Hyung Wook; Baik, Jun Hyun; Park, Cheol Whee; Kim, Young Ok; Yang, Chul Woo; Jin, Dong Chan.
Afiliação
  • Park HS; 1 Division of Nephrology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Choi J; 2 Department of Internal Medicine, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Korea.
  • Kim HW; 3 Department of Radiology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Korea.
  • Baik JH; 1 Division of Nephrology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Park CW; 2 Department of Internal Medicine, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Korea.
  • Kim YO; 3 Department of Radiology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Korea.
  • Yang CW; 1 Division of Nephrology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Jin DC; 1 Division of Nephrology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
J Vasc Access ; 19(3): 252-257, 2018 May.
Article em En | MEDLINE | ID: mdl-29529930
ABSTRACT

PURPOSE:

The exchange from a non-tunneled hemodialysis catheter to a tunneled one over a guidewire using a previous venotomy has been reported to be safe. However, some concerns that it may increase infection risk prevent its clinical application. This approach seems particularly useful for acute kidney injury patients requiring initial renal replacement therapy, in whom we frequently worry about the choice of non-tunneled versus tunneled catheters. MATERIALS AND

METHODS:

From March 2012 to February 2016, 88 cases to receive the over-the-guidewire exchange method from a non-tunneled to a tunneled catheter and 521 cases to receive de novo tunneled catheter placement from the hemodialysis vascular access cohort were compared retrospectively.

RESULTS:

The immediate complication, later catheter dysfunction requiring replacement, and infection rates were comparable between the two groups. Newly placed tunneled catheter survival in the over-the-guidewire exchange group was comparable with survival in the de novo tunneled catheter group (p = 0.24). In addition, when we compared the same two methods among only intensive care unit patients; they remained similar (p = 0.19).

CONCLUSION:

An exchange with the over-the-guidewire method from a non-tunneled to a tunneled catheter was comparable to a de novo catheter placement technique. Therefore, this method should be viewed more favorably and should especially be considered for acute kidney injury patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Grau de Desobstrução Vascular / Cateterismo Venoso Central / Cateteres de Demora / Diálise Renal / Remoção de Dispositivo / Injúria Renal Aguda / Cateteres Venosos Centrais Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Grau de Desobstrução Vascular / Cateterismo Venoso Central / Cateteres de Demora / Diálise Renal / Remoção de Dispositivo / Injúria Renal Aguda / Cateteres Venosos Centrais Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article