Your browser doesn't support javascript.
loading
Ultrasonographic evaluation of the distance between the flexor pollicis longus tendon and volar prominence of the plate as a function of volar plate positioning and pronator quadratus repair - A cadaver study.
Goorens, C K; Van Royen, K; Grijseels, S; Provyn, S; De Mey, J; Scheerlinck, T; Goubau, J F.
Afiliação
  • Goorens CK; Regionaal Ziekenhuis Tienen, Kliniekstraat 45, 3300 Tienen, Belgium; University Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium. Electronic address: cgoorens@msn.com.
  • Van Royen K; University Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium.
  • Grijseels S; University Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium.
  • Provyn S; Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium.
  • De Mey J; University Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium.
  • Scheerlinck T; University Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium.
  • Goubau JF; University Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium.
Hand Surg Rehabil ; 37(3): 171-174, 2018 06.
Article em En | MEDLINE | ID: mdl-29567086
ABSTRACT
Flexor tendon injury after volar plating of distal radius fractures is due to friction against the plate. To assess this risk, the distance between the flexor pollicis longus (FPL) and the volar prominence of the plate was measured with ultrasonography under various conditions a standard plate fixed proximal or distal to the watershed line and a low-profile volar rim plate, with and without transection of the pronator quadratus (PQ). Distance from the FPL to the volar prominence of the plate decreased significantly when the PQ was cut and when a standard plate was placed distal to the watershed line, with the tendon often bulging over the plate. No statistical difference was measured between a volar rim plate and a standard plate distal to the watershed line. Our results confirm the importance of positioning the volar plate proximal to the watershed line and of repairing the PQ.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rádio (Anatomia) / Tendões / Músculo Esquelético Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rádio (Anatomia) / Tendões / Músculo Esquelético Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article