Evaluation of radiation loading on finite cylindrical shells using the fast Fourier transform: A comparison with direct numerical integration.
Liu, S X; Zou, M S.
Afiliação
  • Liu SX; China Ship Scientific Research Center, Wuxi 214082, People's Republic of China liushuxiao@tju.edu.cn, zoumings@126.com.
  • Zou MS; China Ship Scientific Research Center, Wuxi 214082, People's Republic of China liushuxiao@tju.edu.cn, zoumings@126.com.
J Acoust Soc Am ; 143(3): EL160, 2018 03.
Article em En | MEDLINE | ID: mdl-29604690
The radiation loading on a vibratory finite cylindrical shell is conventionally evaluated through the direct numerical integration (DNI) method. An alternative strategy via the fast Fourier transform algorithm is put forward in this work based on the general expression of radiation impedance. To check the feasibility and efficiency of the proposed method, a comparison with DNI is presented through numerical cases. The results obtained using the present method agree well with those calculated by DNI. More importantly, the proposed calculating strategy can significantly save the time cost compared with the conventional approach of straightforward numerical integration.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article