Your browser doesn't support javascript.
loading
Optimal Evaluation of Programmed Death Ligand-1 on Tumor Cells Versus Immune Cells Requires Different Detection Methods.
Schats, Kelly A; Van Vré, Emily A; Boeckx, Carolien; De Bie, Martine; Schrijvers, Dorien M; Neyns, Bart; De Meester, Ingrid; Kockx, Mark M.
Afiliação
  • Kockx MM; From the Departments of Immunohistochemistry (Drs Schats, Van Vré, Boeckx, and Schrijvers and Ms De Bie) and Molecular Pathology (Dr Kockx), HistoGeneX, Antwerp, Belgium; the Department of Medical Biochemistry, University of Antwerp, Antwerp, Belgium (Drs Schats and De Meester); and the Department of Medical Oncology, Universitair Ziekenhuis Brussel, Belgium (Dr Neyns).
Arch Pathol Lab Med ; 142(8): 982-991, 2018 08.
Article em En | MEDLINE | ID: mdl-29607663
ABSTRACT
CONTEXT - The benefit of programmed death ligand-1 (PD-L1) immunohistochemistry (IHC) as a method to select patients who may benefit from programmed death receptor-1 (PD-1)/PD-L1 immunotherapies remains uncertain in many tumor indications.

OBJECTIVES:

- To compare the commercially available, approved PD-L1 IHC assays (22C3, 28-8, SP142, SP263), specifically identifying the changes in staining output created by altering the detection method.

DESIGN:

- This pilot study investigates the respective PD-L1 kit assay staining patterns and related scoring of tumor cells and immune cells on lung carcinoma and melanoma. Furthermore, the influence of the detection method (platform and related reagents) on PD-L1 antibody performance is studied.

RESULTS:

- The SP142 kit reveals more immune cell staining but less tumor cell staining than the other PD-L1 kits. Alternatively, the 22C3 and 28-8 kits show good tumor cell sensitivity, but less pronounced immune cell staining, even in tonsil. Tumor cell staining by the SP263 kit is comparable to that of 22C3 and 28-8 kits, while immune cell staining is better. Strikingly, the selection of the detection method has a major impact on the sensitivity of the assay for PD-L1 detection per cell type. Switching the detection method of the kits could largely circumvent the observed staining differences.

CONCLUSIONS:

- The diverse sensitivities caused by the choice of the detection method should be taken into consideration when selecting PD-L1 kits or developing PD-L1 IHC laboratory-developed tests. When using alternative kits or laboratory-developed tests, it is strongly recommended to reestablish their clinical utility per therapeutic agent or compare them with the original kit.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Biomarcadores Tumorais / Carcinoma Pulmonar de Células não Pequenas / Antígeno B7-H1 / Neoplasias Pulmonares / Melanoma Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Biomarcadores Tumorais / Carcinoma Pulmonar de Células não Pequenas / Antígeno B7-H1 / Neoplasias Pulmonares / Melanoma Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article