Validation of a motion-robust 2D sequential technique for quantification of hepatic proton density fat fraction during free breathing.
Pooler, B Dustin; Hernando, Diego; Ruby, Jeannine A; Ishii, Hiroshi; Shimakawa, Ann; Reeder, Scott B.
Afiliação
  • Pooler BD; Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Hernando D; Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Ruby JA; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Ishii H; Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Shimakawa A; Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Reeder SB; Faculty of Medicine, University of Yamanashi, Yamanashi, Japan.
J Magn Reson Imaging ; 48(6): 1578-1585, 2018 12.
Article em En | MEDLINE | ID: mdl-29665193
ABSTRACT

BACKGROUND:

Current chemical-shift-encoded (CSE) MRI techniques for measuring hepatic proton density fat fraction (PDFF) are sensitive to motion artifacts.

PURPOSE:

Initial validation of a motion-robust 2D-sequential CSE-MRI technique for quantification of hepatic PDFF. STUDY TYPE Phantom study and prospective in vivo cohort. POPULATION Fifty adult patients (27 women, 23 men, mean age 57.2 years). FIELD STRENGTH/SEQUENCE 3D, 2D-interleaved, and 2D-sequential CSE-MRI acquisitions at 1.5T. ASSESSMENT Three CSE-MRI techniques (3D, 2D-interleaved, 2D-sequential) were performed in a PDFF phantom and in vivo. Reference standards were 3D CSE-MRI PDFF measurements for the phantom study and single-voxel MR spectroscopy hepatic PDFF measurements (MRS-PDFF) in vivo. In vivo hepatic MRI-PDFF measurements were performed during a single breath-hold (BH) and free breathing (FB), and were repeated by a second reader for the FB 2D-sequential sequence to assess interreader variability. STATISTICAL TESTS Correlation plots to validate the 2D-sequential CSE-MRI against the phantom and in vivo reference standards. Bland-Altman analysis of FB versus BH CSE-MRI acquisitions to evaluate robustness to motion. Bland-Altman analysis to assess interreader variability.

RESULTS:

Phantom 2D-sequential CSE-MRI PDFF measurements demonstrated excellent agreement and correlation (R2 > 0.99) with 3D CSE-MRI. In vivo, the mean (±SD) hepatic PDFF was 8.8 ± 8.7% (range 0.6-28.5%). Compared with BH acquisitions, FB hepatic PDFF measurements demonstrated bias of +0.15% for 2D-sequential compared with + 0.53% for 3D and +0.94% for 2D-interleaved. 95% limits of agreement (LOA) were narrower for 2D-sequential (±0.99%), compared with 3D (±3.72%) and 2D-interleaved (±3.10%). All CSE-MRI techniques had excellent correlation with MRS (R2 > 0.97). The FB 2D-sequential acquisition demonstrated little interreader variability, with mean bias of +0.07% and 95% LOA of ± 1.53%. DATA

CONCLUSION:

This motion-robust 2D-sequential CSE-MRI can accurately measure hepatic PDFF during free breathing in a patient population with a range of PDFF values of 0.6-28.5%, permitting accurate quantification of liver fat content without the need for suspended respiration. LEVEL OF EVIDENCE 1 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2018;481578-1585.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Processamento de Imagem Assistida por Computador / Hepatopatia Gordurosa não Alcoólica / Espectroscopia de Prótons por Ressonância Magnética / Fígado Tipo de estudo: Observational_studies Limite: Adult / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Processamento de Imagem Assistida por Computador / Hepatopatia Gordurosa não Alcoólica / Espectroscopia de Prótons por Ressonância Magnética / Fígado Tipo de estudo: Observational_studies Limite: Adult / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article