Transcatheter closure of a large patent ductus arteriosus using jugular access in an infant.
Fernandes, Precylia; Assaidi, Anass; Baruteau, Alban-Elouen; Fraisse, Alain.
Afiliação
  • Fernandes P; Department of Paediatric Cardiology, Royal Brompton Hospital, London, UK.
  • Assaidi A; Department of Cardiology, University Hospital, Casablanca, Morocco.
  • Baruteau AE; Department of Paediatric Cardiology, Evelina Children's Hospital, London, UK.
  • Fraisse A; Department of Paediatric Cardiology, Royal Brompton Hospital, London, UK.
J Thorac Dis ; 10(3): E207-E209, 2018 Mar.
Article em En | MEDLINE | ID: mdl-29707375
ABSTRACT
Trans-catheter device closure of patent ductus arteriosus (PDA) via femoral route is the commonly used, safe and effective procedure. Trans-jugular approach has been successfully used in older children with interrupted inferior vena cava. We report a case of successful occlusion of PDA using Amplatzer duct occluder (ADO) via trans-jugular approach following difficulties encountered in gaining femoral venous access. A 6-month-old male infant, weighing 8 kg was admitted for percutaneous catheter closure of PDA. Echocardiogram showed a 4.5 mm duct and left heart dilatation. Femoral venous access was not possible; therefore, we decided to use a trans-jugular approach. The duct was occluded using 8/6 mm ADO. Successful closure of the duct was confirmed with an aortogram. Post procedure echocardiogram showed no residual shunt across the duct. We highlight that trans-catheter closure of PDA using jugular venous access is safe and effective even in infants.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article