Absolute Reliability and Concurrent Validity of the Stryd System for the Assessment of Running Stride Kinematics at Different Velocities.
García-Pinillos, Felipe; Roche-Seruendo, Luis E; Marcén-Cinca, Noel; Marco-Contreras, Luis A; Latorre-Román, Pedro A.
Afiliação
  • García-Pinillos F; Department of Physical Education, Sport and Recreation, University of La Frontera, Temuco, Chile.
  • Roche-Seruendo LE; Department of Physical Therapy, San Jorge University, University Campus, Zaragoza, Spain ; and.
  • Marcén-Cinca N; Department of Physical Therapy, San Jorge University, University Campus, Zaragoza, Spain ; and.
  • Marco-Contreras LA; Department of Physical Therapy, San Jorge University, University Campus, Zaragoza, Spain ; and.
  • Latorre-Román PA; Department of Corporal Expression, University of Jaén, Las Lagunillas Campus, Jaen, Spain.
J Strength Cond Res ; 35(1): 78-84, 2021 Jan 01.
Article em En | MEDLINE | ID: mdl-29781934
ABSTRACT
ABSTRACT García-Pinillos, F, Roche-Seruendo, LE, Marcen-Cinca, N, Marco-Contreras, LA, and Latorre-Román, PA. Absolute reliability and concurrent validity of the Stryd system for the assessment of running stride kinematics at different velocities. J Strength Cond Res 35(1) 78-84, 2021-This study aimed to determine the absolute reliability and to evaluate the concurrent validity of the Stryd system for measuring spatiotemporal variables during running at different velocities (8-20 km·h-1) by comparing data with another widely used device (the OptoGait system). Eighteen trained male endurance runners performed an incremental running test (8-20 km·h-1 with 3-minute stages) on a treadmill. Spatiotemporal parameters (contact time [CT], flight time [FT], step length [SL], and step frequency [SF]) were measured using 2 different devices (Stryd and OptoGait systems). The Stryd system showed a coefficient of variation (CV) <3%, except for FT (3.7-11.6%). The OptoGait achieved CV <4%, except for FT (6.0-30.6%). Pearson correlation analysis showed large correlations for CT and FT, and almost perfect for SL and SF over the entire protocol. The intraclass correlation coefficients partially support those results. Paired t-tests showed that CT was underestimated (p < 0.05, effect size [ES] > 0.7; ∼4-8%), FT overestimated (p < 0.05, ES > 0.7; ∼7-65%), whereas SL and SF were very similar between systems (ES < 0.1, with differences <1%). The Stryd is a practical portable device that is reliable for measuring CT, FT, SL, and SF during running. It provides accurate SL and SF measures but underestimates CT (0.5-8%) and overestimates FT (3-67%) compared with a photocell-based system.