Your browser doesn't support javascript.
loading
Spectral Computed Tomography Angiography With a Gadolinium-based Contrast Agent: First Clinical Imaging Results in Cardiovascular Applications.
Nadjiri, Jonathan; Pfeiffer, Daniela; Straeter, Alexandra S; Noël, Peter B; Fingerle, Alexander; Eckstein, Hans-Henning; Laugwitz, Karl-Ludwig; Rummeny, Ernst J; Braren, Rickmer; Rasper, Michael.
Afiliação
  • Nadjiri J; Departments of Diagnostic and Interventional Radiology.
  • Pfeiffer D; Departments of Diagnostic and Interventional Radiology.
  • Straeter AS; Technical University of Munich, Garching/Munich, Germany.
  • Noël PB; Departments of Diagnostic and Interventional Radiology.
  • Fingerle A; Departments of Diagnostic and Interventional Radiology.
  • Eckstein HH; Technical University of Munich, Garching/Munich, Germany.
  • Laugwitz KL; Departments of Diagnostic and Interventional Radiology.
  • Rummeny EJ; Technical University of Munich, Garching/Munich, Germany.
  • Braren R; Vascular and Endovascular Surgery.
  • Rasper M; Cardiology, Klinikum rechts der Isar, Technical University of Munich, Munich.
J Thorac Imaging ; 33(4): 246-253, 2018 Jul.
Article em En | MEDLINE | ID: mdl-29863589
PURPOSE: Computed tomography angiography (CTA) requires IV application of iodine-based contrast agents. There are several medical conditions in which application is not advisable or even feasible, especially for elective examinations. Novel techniques such as monoenergetic reconstructions from dual-energy computed tomographic (CT) data have been shown to increase radiation attenuation of gadolinium (Gd)-based contrast agents in a phantom model. Therefore, the purpose of the present investigation was to evaluate the technical feasibility and image quality of clinical spectral CTA with a Gd-based contrast agent. MATERIALS AND METHODS: Eleven consecutive patients with common indications for thoracic CTA and contraindications for iodine-based contrast agents were examined using clinical routine doses (0.2 mmol/kg) of Gd-based contrast agent with spectral CT. Monoenergetic reconstructions of the spectral data set were computed. RESULTS: We performed 11 Gd-enhanced CTAs: 9 aortic angiographies, 1 coronary angiography, and 1 angiography of the pulmonary arteries. Image quality of the monoenergetic reconstructions with 40 keV (monoE40) was considered diagnostic by 2 experienced radiologists in each patient; the conventional CT reconstructions did not reach diagnostic image quality. MonoE40 reconstruction resulted in a substantial, ∼2-fold increase of intravascular Gd attenuation compared with the conventional images (P<0.0001). No relevant change of attenuation was observed for the myocardium or the skeletal muscle. CONCLUSIONS: With spectral CT and reconstruction of monoenergetic images with extrapolated 40 keV, Gd-based contrast agent thoracic angiography with clinical doses of Gd is technically feasible. Gd-based CTA seems a valuable alternative in patients with contraindications for iodine-based contrast media.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Intensificação de Imagem Radiográfica / Doenças Cardiovasculares / Meios de Contraste / Angiografia por Tomografia Computadorizada / Compostos Heterocíclicos Tipo de estudo: Prognostic_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Intensificação de Imagem Radiográfica / Doenças Cardiovasculares / Meios de Contraste / Angiografia por Tomografia Computadorizada / Compostos Heterocíclicos Tipo de estudo: Prognostic_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article