Evaluation of the pulmonary artery potential using a 20-polar circumferential catheter and three-dimensional integrated intracardiac echocardiography.
Takahashi, Masayuki; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Tenma, Taro; Watanabe, Masaya; Kamada, Rui; Sasaki, Ryo; Chiba, Yuki; Maeno, Motoki; Anzai, Toshihisa.
Afiliação
  • Takahashi M; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
  • Yokoshiki H; Department of Cardiovascular Medicine, Sapporo City General Hospital, Kita-11, Nishi-13, Chuo-ku, Sapporo, 060-8604, Japan. hisashi.yokoshiki@doc.city.sapporo.jp.
  • Mitsuyama H; Department of Cardiovascular Medicine, Hokkaido Ohno Memorial Hospital, Sapporo, Japan.
  • Tenma T; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
  • Watanabe M; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
  • Kamada R; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
  • Sasaki R; Division of Medical Engineering Center, Hokkaido University Hospital, Sapporo, Japan.
  • Chiba Y; Division of Medical Engineering Center, Hokkaido University Hospital, Sapporo, Japan.
  • Maeno M; Division of Medical Engineering Center, Hokkaido University Hospital, Sapporo, Japan.
  • Anzai T; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
Heart Vessels ; 34(1): 74-83, 2019 Jan.
Article em En | MEDLINE | ID: mdl-29931540
ABSTRACT
Prolongation of the pulmonary artery potentials (PAPs) in response to short coupling intervals was related to polymorphic QRS configurations during the ventricular tachycardia originating above the pulmonary valve (PA-VT). This prospective study was aimed to investigate the mechanisms of polymorphic changes during the PA-VT. We performed the mapping above the pulmonary valve using a 20-polar circumferential catheter and three-dimensional integrated intracardiac echocardiography in 9 consecutive patients with outflow tract arrhythmias undergoing catheter ablation (UMIN ID UMIN000021682). The location of successful ablation was right ventricular outflow tract (RVOT) in 6 patients, above the pulmonary valve in 1 patient, left coronary cusp in 1 patient, and unknown in 1 patient. The PAP was detected in six (67%) patients with bipolar voltage of 0.56 ± 0.27 mV. Pacing from bipolar electrodes of the circumferential catheter located above the pulmonary valve captured the PA myocardium only in 1 patient who had the PA-VT (100% in PA-VT vs 0% in non-PA-VT, P = 0.0046), and slight changes of the QRS morphology was observed in accordance with the conduction delay from the stimulus to activation of the RVOT myocardium. The selective PAP capture with conduction delays evoked by bipolar stimulations through a 20-polar circumferential catheter may be a characteristic property of patients with the PA-VT. Conduction delays within the PA and PA-RVOT junction appears to contribute polymorphic QRS changes during the PA-VT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Taquicardia Ventricular / Ablação por Cateter / Ecocardiografia Tridimensional / Técnicas Eletrofisiológicas Cardíacas / Cateteres Cardíacos / Sistema de Condução Cardíaco Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Taquicardia Ventricular / Ablação por Cateter / Ecocardiografia Tridimensional / Técnicas Eletrofisiológicas Cardíacas / Cateteres Cardíacos / Sistema de Condução Cardíaco Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article