Your browser doesn't support javascript.
loading
Insight into the characteristics, removal, and toxicity of effluent organic matter from a pharmaceutical wastewater treatment plant during catalytic ozonation.
Wen, Shuhan; Chen, Lin; Li, Weiqi; Ren, Hongqiang; Li, Kan; Wu, Bing; Hu, Haidong; Xu, Ke.
Afiliação
  • Wen S; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China.
  • Chen L; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China.
  • Li W; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China.
  • Ren H; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China.
  • Li K; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China.
  • Wu B; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China.
  • Hu H; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China.
  • Xu K; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, N.O.163, Xianlin Avenue, Qixia District, Nanjing, 210023, Jiangsu, PR China. kexu@nju.edu.cn.
Sci Rep ; 8(1): 9581, 2018 06 25.
Article em En | MEDLINE | ID: mdl-29941941
ABSTRACT
Changes in the characteristics, removal efficiency, and toxicity of pharmaceutical effluent organic matter (EfOM) after catalytic ozonation were investigated in this study. After a 90-min treatment with a catalytic ozonation process (COP) in the presence of MnO2 ceramsite, the total organic carbon (TOC), UV254, colority, protein, and humic acid removal rates were 13.24%, 60.83%, 85.42%, 29.36% and 74.19%, respectively. The polysaccharide content increased by 12.73 mg/L during the COP for reaction times between 0 and ~50 min and decreased by 6.97 mg/L between 50 and ~90 min. Furthermore, 64.44% of the total colority was detected in the hydrophobic organic matter (HOM) fraction, and after the COP, and 88.69% of the colority in the HOM was eliminated. Meanwhile, only 59.18% of the colority in the hydrophilic organic matter (HIM) fraction was removed. GC-MS analysis showed that 38 organic pollutant species were completely removed, 8 were partially removed, and 7 were generated. After 90 min of COP treatment, the pharmaceutical EfOM toxicity was effectively reduced based on the higher incubation and lower mortality rates.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article