Your browser doesn't support javascript.
loading
An integration of fast alignment and maximum-likelihood methods for electron subtomogram averaging and classification.
Zhao, Yixiu; Zeng, Xiangrui; Guo, Qiang; Xu, Min.
Afiliação
  • Zhao Y; Computational Biology and Computer Science Departments, School of Computer Science, Carnegie Mellon University, Pittsburgh, PA, USA.
  • Zeng X; Computational Biology and Computer Science Departments, School of Computer Science, Carnegie Mellon University, Pittsburgh, PA, USA.
  • Guo Q; Department of Molecular Structural Biology, Max Planck Institute of Biochemistry, Martinsried, Germany.
  • Xu M; Computational Biology and Computer Science Departments, School of Computer Science, Carnegie Mellon University, Pittsburgh, PA, USA.
Bioinformatics ; 34(13): i227-i236, 2018 07 01.
Article em En | MEDLINE | ID: mdl-29949977
Motivation: Cellular Electron CryoTomography (CECT) is an emerging 3D imaging technique that visualizes subcellular organization of single cells at sub-molecular resolution and in near-native state. CECT captures large numbers of macromolecular complexes of highly diverse structures and abundances. However, the structural complexity and imaging limits complicate the systematic de novo structural recovery and recognition of these macromolecular complexes. Efficient and accurate reference-free subtomogram averaging and classification represent the most critical tasks for such analysis. Existing subtomogram alignment based methods are prone to the missing wedge effects and low signal-to-noise ratio (SNR). Moreover, existing maximum-likelihood based methods rely on integration operations, which are in principle computationally infeasible for accurate calculation. Results: Built on existing works, we propose an integrated method, Fast Alignment Maximum Likelihood method (FAML), which uses fast subtomogram alignment to sample sub-optimal rigid transformations. The transformations are then used to approximate integrals for maximum-likelihood update of subtomogram averages through expectation-maximization algorithm. Our tests on simulated and experimental subtomograms showed that, compared to our previously developed fast alignment method (FA), FAML is significantly more robust to noise and missing wedge effects with moderate increases of computation cost. Besides, FAML performs well with significantly fewer input subtomograms when the FA method fails. Therefore, FAML can serve as a key component for improved construction of initial structural models from macromolecules captured by CECT. Availability and implementation: http://www.cs.cmu.edu/mxu1.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Software / Modelos Moleculares / Substâncias Macromoleculares / Tomografia com Microscopia Eletrônica Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Software / Modelos Moleculares / Substâncias Macromoleculares / Tomografia com Microscopia Eletrônica Idioma: En Ano de publicação: 2018 Tipo de documento: Article