Your browser doesn't support javascript.
loading
Analysis of the Marginal Fit and Dimensional Stability of Cast-to Cobalt-Chromium Implant Cylinders Cast from Different Alloys.
Int J Prosthodont ; 31(4): 367-369, 2018.
Article em En | MEDLINE | ID: mdl-29953568
ABSTRACT

PURPOSE:

To evaluate the influence of cobalt-chromium (Co-Cr) casting alloys' melting temperatures on the cast-to Co-Cr implant cylinders' marginal fit. MATERIALS AND

METHODS:

Co-Cr alloys with different melting ranges were cast into 20 Co-Cr cylinders 10 in a high-melting temperature (HMT) group and 10 in a low-melting temperature (LMT) group. Ten cylinders were used as received as a control group. Cylinders' marginal misfit and dimensional stability were evaluated using scanning electron microscopy (×500). RESULTS AND

CONCLUSION:

HMT cylinders showed significant differences in marginal misfit (2.48 ± 1.07 µm2) compared to LMT (1.53 ± 0.37 µm2) and control (1.27 ± 0.57 µm2) cylinders, but there were no differences in dimensional stability. HMT Co-Cr alloys produce implant-supported prostheses with poor marginal fit.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ligas de Cromo / Técnica de Fundição Odontológica / Adaptação Marginal Dentária Idioma: En Ano de publicação: 2018 Tipo de documento: Article