Your browser doesn't support javascript.
loading
Measurement of (Aptamer-Small Target) KD Using the Competition between Fluorescently Labeled and Unlabeled Targets and the Detection of Fluorescence Anisotropy.
Samokhvalov, Alexey V; Safenkova, Irina V; Eremin, Sergei A; Zherdev, Anatoly V; Dzantiev, Boris B.
Afiliação
  • Samokhvalov AV; A.N. Bach Institute of Biochemistry , Research Center of Biotechnology of the Russian Academy of Sciences , Moscow 119071 , Russia.
  • Safenkova IV; A.N. Bach Institute of Biochemistry , Research Center of Biotechnology of the Russian Academy of Sciences , Moscow 119071 , Russia.
  • Eremin SA; Faculty of Chemistry , M.V. Lomonosov Moscow State University , Moscow 119991 , Russia.
  • Zherdev AV; A.N. Bach Institute of Biochemistry , Research Center of Biotechnology of the Russian Academy of Sciences , Moscow 119071 , Russia.
  • Dzantiev BB; A.N. Bach Institute of Biochemistry , Research Center of Biotechnology of the Russian Academy of Sciences , Moscow 119071 , Russia.
Anal Chem ; 90(15): 9189-9198, 2018 08 07.
Article em En | MEDLINE | ID: mdl-29961317
ABSTRACT
Registration of fluorescence anisotropy (FA) allows for characterizing the interactions of ligands with aptamers and other receptors under homogeneous conditions without reagent immobilization, prolonged incubations, and product separation. We proposed an approach for aptamer affinity determination by FA taking into account the difference in label fluorescence before and after complexation. The detailed step by step scheme using a native and fluorescently labeled ligand was described and justified in the paper. The scheme ensures the exclusion of data with low reliability and establishes valid criteria for selecting optimal concentrations of reagents (labeled ligand and aptamer) used in the experiments. The approach was experimentally tested using ochratoxin A (OTA), its fluorescein-labeled derivative (OTA-Flu), and the aptamer binding them. We demonstrated that it allows minimizing the influence of fluorescence change to accurately determine the dissociation constant. On the basis of FA registration, the binding constants of the aptamer-OTA-Flu and the aptamer-OTA complexes were found to be equal to 245 + 33 and 63 + 18 nM, respectively. The value for the aptamer-OTA complexes was confirmed by the equilibrium dialysis technique. The resulting constant was 80 ± 9 nM. The versatility and methodological simplicity of the proposed protocol, as well as the short implementation time, are why it can be recommended as an effective tool for characterizing aptamer-ligand complexes.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article