[Application of a Two-stage Virtual Impactor in Measuring of PM10 and PM2.5 Emissions from Stationary Sources].
Huan Jing Ke Xue
; 37(6): 2003-2007, 2016 Jun 08.
Article
em Zh
| MEDLINE
| ID: mdl-29964863
ABSTRACT
Recently, the Ministry of Environmental Protection of China started the development of emission inventories in fifteen Chinese cities. It includes the esmission of PM10 and PM2.5 from stationary sources. However, there is no national standard method in China for stationary source PM10 and PM2.5 sampling. In this study, a two-stage virtual impactor was developed for sampling PM10 and PM2.5 from stationary sources. Its performance was evaluated for four types of sataionary sources, i.e., coal-fired power plant, waste incineration, circulating fluid bed, and converter steelmaking. These four tested emission sources were equipped with high efficiency PM control devices. PM2.5 mass concentrations measured in the chimneys of these emission sources were (0.93±0.03), (3.3±0.65), (0.59±0.04), and (0.15±0.04) mg·m-3, respectively, while the PM10 mass concentrations were (1.13±0.11), (6.9±0.86), (1.12±0.16), and (0.43±0.15) mg·m-3, respectively.