Your browser doesn't support javascript.
loading
Towards spill-free in-bag morcellation: a health failure mode and effects analysis.
van den Haak, Lukas; van der Eijk, Anne C; Sandberg, Evelien M; Frank, Gerard Peter G M; Ansink, Karin; Pelger, Rob C M; de Kroon, Cor D; Jansen, Frank Willem.
Afiliação
  • van den Haak L; Department of Gynecology, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • van der Eijk AC; Central Sterile Supply Department, Leiden University Medica Centre, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • Sandberg EM; Department of Gynecology, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • Frank GPGM; Department of Gynecology, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • Ansink K; Operating Room Center, Leiden University Medica Centre, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • Pelger RCM; Department of Urology, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • de Kroon CD; Department of Gynecology, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.
  • Jansen FW; Department of Gynecology, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands. f.w.jansen@lumc.nl.
Surg Endosc ; 32(10): 4357-4362, 2018 10.
Article em En | MEDLINE | ID: mdl-29987561
ABSTRACT

BACKGROUND:

To assess potential risks of new surgical procedures and devices before their introduction into daily practice, a prospective risk inventory (PRI) is a required step. This study assesses the applicability of the Health Failure Mode and Effects Analysis (HFMEA) as part of a PRI of new technology in minimally invasive gynecologic surgery.

METHODS:

A reference case was defined of a patient with presumed benign leiomyoma undergoing a laparoscopic hysterectomy or myomectomy including in-bag power morcellation; however, pathology defined a stage I uterine leiomyosarcoma. Using in-bag morcellation as a template, a HFMEA was performed. All steps of the in-bag morcellation technique were identified. Next, the possible hazards of these steps were explored and possible measures to control these hazards were discussed.

RESULTS:

Five main steps of the morcellation process were identified. For retrieval bags without openings to accommodate instruments inside the bag, 120 risks were identified. Of these risks, 67 should be eliminated. For containment bags with openings 131 risks were identified of which 68 should be eliminated. Of the 10 causes most at risk to cause spillage, two can be eliminated by using appropriate bag materials. Myomectomy appears to be more at risk for residual tissue spillage compared to total hysterectomy.

CONCLUSION:

The HFMEA has provided important new insights regarding potential weaknesses of the in-bag morcellation technique, particularly with respect to hazardous steps in the morcellation process as well as requirements that bags should meet. As such, this study has shown HFMEA to be a valuable method that identifies and quantifies potential hazards of new technology.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Uterinas / Laparoscopia / Miomectomia Uterina / Morcelação / Histerectomia / Leiomiossarcoma Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Female / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Uterinas / Laparoscopia / Miomectomia Uterina / Morcelação / Histerectomia / Leiomiossarcoma Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Female / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article