A calibration framework for the determination of accurate collision cross sections of polyanions using polyoxometalate standards.
Hupin, Sébastien; Lavanant, Hélène; Renaudineau, Séverine; Proust, Anna; Izzet, Guillaume; Groessl, Michael; Afonso, Carlos.
Afiliação
  • Hupin S; Normandie Univ, UNIROUEN, INSA Rouen, CNRS, COBRA, 76000, Rouen, France.
  • Lavanant H; Normandie Univ, UNIROUEN, INSA Rouen, CNRS, COBRA, 76000, Rouen, France.
  • Renaudineau S; Sorbonne Universités, UPMC Univ Paris 06, CNRS UMR 8232, Institut Parisien de Chimie Moléculaire, 4 Place Jussieu, F-75005, Paris, France.
  • Proust A; Sorbonne Universités, UPMC Univ Paris 06, CNRS UMR 8232, Institut Parisien de Chimie Moléculaire, 4 Place Jussieu, F-75005, Paris, France.
  • Izzet G; Sorbonne Universités, UPMC Univ Paris 06, CNRS UMR 8232, Institut Parisien de Chimie Moléculaire, 4 Place Jussieu, F-75005, Paris, France.
  • Groessl M; Department of Nephrology and Hypertension and Department of BioMedical Research, Inselspital, Bern University Hospital, University of Bern, Switzerland.
  • Afonso C; Normandie Univ, UNIROUEN, INSA Rouen, CNRS, COBRA, 76000, Rouen, France.
Rapid Commun Mass Spectrom ; 32(19): 1703-1710, 2018 Oct 15.
Article em En | MEDLINE | ID: mdl-29989245
RATIONALE: Polyoxometalates (POMs) are remarkable oxo-clusters forming compact highly charged anions. We measured their collision cross sections (CCS) in N2 with drift tube ion mobility spectrometry (DTIMS). These values were then used to calibrate a traveling wave ion mobility spectrometry (TWIMS) device and the accuracy of the calibration was tested. METHODS: Six POM standards were analyzed by DTIM-MS (Tofwerk, Thun, Switzerland) at different voltages to determine absolute DT CCS (N2 ) values. Five POM compounds (Lindqvist TBA2 Mo6 O19; decatungstate TBA4 W10 O32; Keggin TBA3 PMo12 O40 ; TBA3 PW12 O40 and Dawson TBA6 P2 W18 O62 ) were used for the calibration of the TWIM-MS instrument (Synapt G2 HDMS, Waters, Manchester, UK) and a sixth Dawson POM, TBA9 P2 Nb3 W15 O62 , was used to compare the accuracy of the calibrations with POM or with polyalanine and dextran reference ions. RESULTS: We determined 45 DT CCS (N2 ) values at 30°C or 60°C. Fourteen DT CCS (N2 ) values at 30°C were used to perform calibration of the TWIMS instrument. Better correlations were observed than when DT CCS values in helium from the literature were used. The accuracy tests on six ions of Dawson POM TBA9 P2 Nb3 W15 O62 led to relative errors below 3.1% while relative errors of 3.6% to 10.1% were observed when calibration was performed with polyalanine and dextran reference ions. CONCLUSIONS: Our novel calibration strategy for determination of CCS values of multiply negatively charged ions on TWIM-MS devices based on DT CCS (N2 ) of standard POM structures covered a wider range of CCS and improved the accuracy to 2.1% relative error on average compared with 6.9% using polyalanine and dextran calibration.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article