Your browser doesn't support javascript.
loading
Intrasession and Between-Visit Variability of Retinal Vessel Density Values Measured with OCT Angiography in Diabetic Patients.
Czakó, Cecília; Sándor, Gábor; Ecsedy, Mónika; Récsán, Zsuzsa; Horváth, Hajnalka; Szepessy, Zsuzsanna; Nagy, Zoltán Zsolt; Kovács, Illés.
Afiliação
  • Czakó C; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary.
  • Sándor G; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary.
  • Ecsedy M; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary.
  • Récsán Z; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary.
  • Horváth H; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary.
  • Szepessy Z; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary.
  • Nagy ZZ; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary.
  • Kovács I; Department of Ophthalmology, Semmelweis University, 26 Ülloi Street, 1085, Budapest, Hungary. kovacsilles@yahoo.com.
Sci Rep ; 8(1): 10598, 2018 Jul 13.
Article em En | MEDLINE | ID: mdl-30006592
ABSTRACT
In clinical practice the measurement error of an instrument has special importance in analyzing and interpreting data, and acknowledging limitations. The purpose of this study was to evaluate intrasession and between-visit reproducibility of OCT angiography measurements in diabetic patients. A total of 54 eyes of 27 diabetic patients underwent OCT angiography imaging. Foveal avascular zone (FAZ) area and superficial retinal vessel density (VD) at 3 mm were calculated using the AngioAnalytics software. Three consecutive images were acquired at first visit and one image 1 month later. Intrasession and between-visit reproducibility of parameters were characterized by intraclass correlation coefficient (ICC), coefficient of variation (CV), and coefficient of repeatability (CR) values. We measured excellent (>0.90) ICC values both in intrasession and between-visit comparisons. CV was higher for the FAZ area compared to VD both in intrasession (7.79% vs. 2.87%) and in between-visit (12.33% vs. 2.95%) comparisons. Between-visit CR value for VD was 4.53% (95% CI 3.72-5.79%). These data suggest that OCT angiography shows excellent repeatability in diabetic patients, indicating that this non-invasive technology might be suitable for longitudinal assessment of microvascular complications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Angiografia / Tomografia de Coerência Óptica / Retinopatia Diabética Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Angiografia / Tomografia de Coerência Óptica / Retinopatia Diabética Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article