Your browser doesn't support javascript.
loading
Poly(styrene-4-sulfonate)-protected copper nanoclusters as a fluorometric probe for sequential detection of cytochrome c and trypsin.
Hu, Yanling; He, Yu; Han, Yaxue; Ge, Yili; Song, Gongwu; Zhou, Jiangang.
Afiliação
  • Hu Y; Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Wuhan, 430062, China.
  • He Y; Ministry-of-Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, China.
  • Han Y; Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Wuhan, 430062, China. heyu@hubu.edu.cn.
  • Ge Y; Ministry-of-Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, China. heyu@hubu.edu.cn.
  • Song G; Hubei Province Key Laboratory of Regional Development and Environment Response, Wuhan, 430062, China. heyu@hubu.edu.cn.
  • Zhou J; Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Wuhan, 430062, China.
Mikrochim Acta ; 185(8): 383, 2018 07 21.
Article em En | MEDLINE | ID: mdl-30032328
ABSTRACT
Stable copper nanoclusters (CuNCs) were prepared by utilizing D-penicillamine as both the stabilizer and reductant. The emission of the CuNCs (with excitation/emission peaks at 390/645 nm) is largely stabilized by coating with poly(sodium-p-styrenesulfonate) (PSS). Cytochrome c (Cyt c) quenches the fluorescence of the PSS-coated CuNCs, and this effect was exploited to design a quenchometric fluorometric assay for Cyt c. If trypsin is added to the loaded CuNCs, it will hydrolyze Cyt c to form peptide fragments, and fluorescence is gradually restored. A highly sensitive and fluorometric turn-off-on assay was constructed for sequential detection of Cyt c and trypsin. The linear ranges for Cyt c and trypsin are from 8.0 nM to 680 nM, and from 0.1 to 6.0 µg mL-1, and the lower detection limits are 0.83 nM and 20 ng mL-1 for Cyt c and trypsin, respectively. Graphical abstract Schematic illustration of the fluorometric assay for trypsin based on the electron transfer between poly(p-styrenesulfonate)-protected copper nanoclusters (PSS-CuNCs) and cytochrome c (Cyt c).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliestirenos / Tripsina / Cobre / Citocromos c / Nanopartículas Metálicas / Corantes Fluorescentes / Fluorometria Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliestirenos / Tripsina / Cobre / Citocromos c / Nanopartículas Metálicas / Corantes Fluorescentes / Fluorometria Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article