Your browser doesn't support javascript.
loading
Loop microcatheter technique for coil embolization of paraclinoid aneurysms.
Jia, Zhen Yu; Song, Yun Sun; Sheen, Jae Jon; Kim, Joong Goo; Lee, Chae Woon; Suh, Dae Chul.
Afiliação
  • Jia ZY; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, South Korea.
  • Song YS; Department of Radiology, The First Affiliated Hospital with Nanjing Medical University, 300 Guangzhou Road, Nanjing, 210029, Jiangsu Province, China.
  • Sheen JJ; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, South Korea.
  • Kim JG; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, South Korea.
  • Lee CW; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, South Korea.
  • Suh DC; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, South Korea.
Acta Neurochir (Wien) ; 160(9): 1755-1760, 2018 09.
Article em En | MEDLINE | ID: mdl-30056517
ABSTRACT

BACKGROUND:

Although paraclinoid aneurysms do not exhibit a high risk of rupture, coil embolization is not always easy because of unstable microcatheter position. We present a technique that allows a stable microcatheter position for coil embolization of paraclinoid aneurysms.

METHODS:

We enrolled 34 consecutive patients who underwent coil embolization for paraclinoid aneurysms. A loop of distal microcatheter was shaped based on three-dimensional rotational angiography. The basic concept is to keep the proximal loop abutting the opposite wall of the aneurysm while using the distal loop for coiling. Then, a proximal curve was made to accommodate the shape of the carotid siphon, which may decide the direction of the loop. Stent-assisted coil embolization was performed in 19 wide-necked aneurysms. Immediate radiological outcomes were analyzed with Raymond classification and clinical outcomes were evaluated with modified Rankin Scale (mRS) scores.

RESULTS:

Satisfactory occlusion of aneurysm was achieved in 94.1% (32/34) of patients with a Raymond score of 1 or 2. Packing density of ≥ 31% was achieved in 71% (24/34) of patients. No significant differences were observed between stent-assisted coiling and coiling-only groups. Follow-up magnetic resonance angiography and/or angiogram showed stable coil position, except in one patient with tiny recurrence (from Raymond scores 1 to 2) that did not require retreatment at the 6-month follow-up. mRS scores of 0-1 were obtained in all patients at 6 months.

CONCLUSIONS:

Loop microcatheter technique allowed safe and stable coil packing for paraclinoid aneurysms. The same procedural concept is also being used for aneurysms in other vascular territories.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolização Terapêutica Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolização Terapêutica Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article