Your browser doesn't support javascript.
loading
Formulation of chelating agent with surfactant in cloud point extraction of methylphenol in water.
Hazrina, H Z; Noorashikin, M S; Beh, S Y; Loh, S H; Zain, N N M.
Afiliação
  • Hazrina HZ; School of Marine Science and Environment, Universiti Malaysia Terengganu, 21030 Kuala Terengganu, Terengganu, Malaysia.
  • Noorashikin MS; Chemical Engineering Programme, Research Centre For Sustainable Process Technology (CESPRO), Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor, Malaysia.
  • Beh SY; Chemical Engineering Programme, Research Centre For Sustainable Process Technology (CESPRO), Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor, Malaysia.
  • Loh SH; School of Marine Science and Environment, Universiti Malaysia Terengganu, 21030 Kuala Terengganu, Terengganu, Malaysia.
  • Zain NNM; Integrative Medicine Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, 13200 Kepala Batas, Pulau Pinang, Malaysia.
R Soc Open Sci ; 5(7): 180070, 2018 Jul.
Article em En | MEDLINE | ID: mdl-30109066
ABSTRACT
Cloud point extraction (CPE) is a separation and preconcentration of non-ionic surfactant from one liquid phase to another. In this study, Sylgard 309 and three different types of additives for CPE, namely CPE-Sylgard, CPE-Sylgard-BMIMBr and CPE-Sylgard-GLDA, are investigated to extract methylphenol from water samples. The methylphenols are well separated by reversed-phase high-performance liquid chromatography (HPLC) with isocratic elution of acetonitrile water; 60 40 (v/v) and detection at 260 nm. The optimized parameters for the effect of salt, surfactant, temperature, time of extraction, pH, interference study and the performance of different additives on methylphenol extraction are investigated. CPE-Sylgard-GLDA is chosen because it gives us a high peak and good peak area compared with CPE-Sylgard and CPE-Sylgard-BMIMBr. The recovery extractions of CPE-Sylgard-GLDA are obtained in the range of 80-99% as the percentage of relative standard deviation (RSD) is less than 10. The LOD and LOQ are 0.05 ppm and 0.18 ppm, respectively. The method developed for CPE-Sylgard-GLDA coupled with HPLC is feasible for the determination of methylphenol because it is simple, effective, cheap, and produces a high percentage of recovery.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article