Your browser doesn't support javascript.
loading
Effect of reduction quality on post-operative outcomes in 31-A2 intertrochanteric fractures following intramedullary fixation: a retrospective study based on computerised tomography  findings.
Li, Jiantao; Zhang, Licheng; Zhang, Hao; Yin, Peng; Lei, Mingxing; Wang, Guoqi; Wang, Song; Tang, Peifu.
Afiliação
  • Li J; Department of Orthopaedics, Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China.
  • Zhang L; Department of Orthopaedics, Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China.
  • Zhang H; Department of Orthopaedics, Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China.
  • Yin P; Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gong Ren Ti Yu Chang Nan Lu Rd, Beijing, 100020, China.
  • Lei M; Department of Orthopaedics, Hainan Branch of Chinese PLA General Hospital, Sanya, 572013, Hainan, China.
  • Wang G; Department of Orthopaedics, Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China.
  • Wang S; Medical College, Nankai University, No. 94 Weijin Road, Tianjin, 300071, China.
  • Tang P; Department of Orthopaedics, Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China. pftang301@163.com.
Int Orthop ; 43(8): 1951-1959, 2019 08.
Article em En | MEDLINE | ID: mdl-30116869
PURPOSE: To determine how the reduction of medial and anteromedial cortices using CT findings in 31-A2 intertrochanteric fractures treated with the intramedullary nail could affect the clinical outcomes and complication rates of the fractures. METHODS: We retrospectively analyzed the data of 43 patients with 31-A2 intertrochanteric fractures who underwent closed reduction and intramedullary internal fixation (CRIF) between January 2010 and December 2013. Patients were classified into two groups based on the post-operative CT scans taken from the sagittal and coronal planes, respectively. Five radiographic parameters and three clinical parameters were used to evaluate the post-operative functional states and mobilization levels in this study. Post-operative complications were also recorded. RESULTS: The mean loss of the femoral neck-shaft angle (FNSA) was significantly smaller in Group C1 than that in Group C2. There were significant differences in the sliding distance of the cephalic nail and the loss of femoral head height between the two groups. In terms of the reduction conditions shown on the sagittal planes, the FNSA, sliding distance of the cephalic nail, and the loss of FHH were significantly different, although differences in TCD were not significant. Patients in groups C1 (3.6%) and S1 (0.0%) had lower complication rates compared to patients in groups C2 (26.7%) and S2 (27.8%). CONCLUSION: Patients with good reduction quality of the medial and anteromedial sustainable cortices had better clinical outcomes and lower complication rates. The sustainable stability and anti-rotational function of these validated reductions might play a critical role in maintaining the fragment positions and reducing the incidence of complications in patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fixação Intramedular de Fraturas / Fraturas do Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fixação Intramedular de Fraturas / Fraturas do Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article