Influence of nonthermal argon plasma on the shear bond strength between zirconia and different adhesives and luting composites after artificial aging.
Pott, Philipp-Cornelius; Syväri, Timo-Sebastian; Stiesch, Meike; Eisenburger, Michael.
Afiliação
  • Pott PC; Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
  • Syväri TS; Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
  • Stiesch M; Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
  • Eisenburger M; Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
J Adv Prosthodont ; 10(4): 308-314, 2018 Aug.
Article em En | MEDLINE | ID: mdl-30140398
ABSTRACT

PURPOSE:

Plasma activation of hydrophobic zirconia surfaces might be suitable to improve the bond strength of luting materials. The aim of this study was to analyze the influence of nonthermal argon-plasma on the shear bond strength (SBS) between zirconia and different combinations of 10-MDP adhesive systems and luting composites after artificial aging. MATERIALS AND

METHODS:

Two hundred forty Y-TZP specimens were ground automatically with 165 µm grit and water cooling. Half of the specimens received surface activation with nonthermal argon-plasma. The specimens were evenly distributed into three groups according to the adhesive systems ([Futurabond U, Futurabond M, Futurabond M + DCA], VOCO GmbH, Germany, Cuxhaven) and into further two subgroups according to the luting materials ([Bifix SE, Bifix QM], VOCO GmbH). Each specimen underwent artificial aging by thermocycling and water storage. SBS was measured in a universal testing machine. Statistical analysis was performed using ANOVA and Scheffè procedure with the level of significance set to 0.05.

RESULTS:

Surface activation with nonthermal plasma did not improve the bond strength between zirconia and the tested combinations of adhesive systems and luting materials. The plasma-activation trended to reveal higher bond strength if the self-etch luting material (Bifix SE) was used, irrespective of the adhesive system.

CONCLUSION:

Plasma-activation seems to be suitable to improve bond strength between zirconia and self-etch resin materials. However, further research is necessary to identify the influence of varying plasma-parameters.