Your browser doesn't support javascript.
loading
Second-generation bi-cruciate stabilized total knee system has a lower reoperation and revision rate than its predecessor.
Christen, Bernhard; Kopjar, Branko.
Afiliação
  • Christen B; CHRISTENORTHO AG, Schaenzlistrasse 39, 3000, Bern 25, Switzerland. b.christen@christenortho.ch.
  • Kopjar B; Department of Health Services, University of Washington, Seattle, WA, USA.
Arch Orthop Trauma Surg ; 138(11): 1591-1599, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30167859
ABSTRACT

INTRODUCTION:

Total knee arthroplasty (TKA) can provide pain relief and good long-term results. However, nearly 30% of post-surgical patients are unsatisfied due to persistent pain and functional deficits. A second-generation bi-cruciate stabilized TKA device has a post-cam mechanism with an asymmetric femoral component, a polyethylene insert, and a medially concave and laterally convex shape. The device is designed to provide guided motion, and thus improve knee kinematics by more closely approximating a normal knee. The aim of this study was to evaluate early complication and revision rates of the second-generation device and to compare its clinical performance to the first-generation device. MATERIALS AND

METHODS:

In this retrospective, longitudinal, non-concurrent cohort study, 140 TKAs were performed using the second-generation device on 131 patients from 2012 to 2016, and 155 TKAs were performed using the first-generation device on 138 patients from 2009 to 2012. Primary outcomes were occurrence of revisions and reoperations.

RESULTS:

There were 31 reoperations [3.21 per 100 observed component years (OCY)] in 22 (2.28 per 100 OCY) TKAs in the first-generation device cohort compared to five reoperations (1.92 per 100 OCY) in four TKAs (1.54 per 100 OCY) in the second-generation device cohort. The adjusted hazard ratio (HR) was 3.50 (P = 0.0254). There were 21 revisions (2.17 per 100 OCY) in 16 (1.66 per 100 OCY) TKAs in the first-generation device cohort, compared to only three revisions (1.15 per 100 OCY) in two TKAs (0.77 per 100 OCY) in the second-generation device cohort. The adjusted HR was 4.16 (P = 0.0693).

CONCLUSION:

The improved design of the second-generation device appears to be associated with a lower risk of reoperation and revision compared to that of the first-generation device. LEVEL OF EVIDENCE III.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Artroplastia do Joelho / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Artroplastia do Joelho / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article